TROUBLESHOOTING

PROBLEM: Low or No Output Voltage

Reason/Solution

1.Poor contact at terminals. Unplug and reinsert PI-140.

2.Equipment being operated is drawing too much power.

Use a higher capacity inverter or do not use the device.

3.Inverter is too hot (thermal shut down).

Allow inverter to cool. Check for adequate ventila- tion. Reduced the load on the inverter to rated continuous power output.

4.Fuse blows.

A blown fuse is usually caused by reverse polarity or a short circuit within the device being operated. To replace:

Disconnect the device immediately.

Find the source of the problem, and repair it.

Install a new 15-amp fuse. Do not tighten the fuse cap too far; finger tight is sufficient.

Note: Installing a fuse higher than 15-amps may cause damage to the inverter.

5.Inverter may be defective.

See warranty and call Customer Service 800-621- 5485 (Hours: 7 a.m. – 4:30 p.m. CST).

Image 6
Contents Power Inverter PI-140 Send Warranty Product Repairs toImportant safety Instructions Before Using PI-140 Power Inverter Operating InstructionsPower Source Usage Examples LED Indicator and Overload ProtectionReset Device Type Estimate WattageInverter is too hot thermal shut down TroubleshootingProblem Low or No Output Voltage Fuse blowsSpecifications Replacement PartsFuse 15 Amp Limited Warranty