Senatek LS100 manual IP Address Configuration, IP configuration parameters

Page 23

3: IP Address Configuration

A valid IP address of the LS100 needs to be assigned before it starts to work in the user's network environment. A network system administrator may provide the user with this IP address setting information for the network. The IP address must be unique within the network. Otherwise, the LS100 will not have a valid connection to the network.

Users can choose the desired IP mode out of the three IP operating modes, i.e., Static IP, DHCP and PPPoE. The factory default IP mode is DHCP mode. Table 3-1 shows the parameter items for IP configuration.

 

Table 3-1 IP configuration parameters

 

 

 

Static IP

 

IP address

 

 

Subnet mask

 

 

Default gateway

DHCP

 

No parameters required

PPPoE

 

PPPoE username

 

 

PPPoE password

Basic ‘set’ command usage for IP configuration is as follows:

set ip ipmode par1 par2 ...

where,

ipmode: ‘static’ for Static IP / ‘dhcp’ for DHCP / ‘pppoe’ for PPPoE parameters:

if ipmode = static,

par1 = IP address, par2 = subnet mask, par3 = gateway if ipmode = dhcp,

no parameters required if ipmode = pppoe,

par1 = PPPoE username, par2 = PPPoE password

23

Image 23
Contents HelloDevice Lite Series LS100 User Guide User Guide for the HelloDevice LS100 Contents Page Overview IntroductionPackage Check List Serial Interface Product SpecificationMAC address Terminologies and AcronymsAcronym Table Panel Layout Getting StartedPanel layout of the LS100 Connecting to the Network Connecting the HardwareConnecting the Power Connecting a network cable to the LS100 Connecting to the DeviceUsing Serial Console Accessing Console PortData/Console switch of the LS100 Telnet program set up example Using Remote ConsoleLS100 command set summary Command UsageIP configuration example screen 1 ‘set’ Command11 Help screen example 2 ‘get’ Command14 Getting all parameters screen 3 ‘help’ Command15 Help screen 4 ‘factorydefault’ Command7 ‘reboot’ Command 5 ‘save’ Command6 ‘exit’ Command IP configuration parameters IP Address ConfigurationOverview Static IP ConfigurationStatic IP Dhcp Setting IP configuration parameters for Static IP modePPPoE Dhcp ConfigurationPPPoE Configuration LS100 TCP/IP session modes Host Mode ConfigurationHost mode configuration parameters Listen Sync-Sent TCP Server Mode OperationsSync-Recvd Listen TCP server mode setting TCP Server Mode ConfigurationOperations Serial data transfer TCP Client Mode OperationsState Transition Diagram of TCP client mode TCP Client Mode ConfigurationTCP client mode setting TCP Server/Client Mode OperationsState Transition Diagram of TCP server/client mode TCP Server/Client Mode ConfigurationTCP server/client mode setting Serial Port Configuration parameters Serial Port ConfigurationSet serial 9600 7 e 2 h s n Serial port configuration Administration parameters configuration System AdministrationSerial Port Pin Outs Appendix a ConnectionsEthernet Pin outs HelloDevice Ethernet Wiring DiagramSerial Wiring Diagram Table B-1 Well-known port numbers Appendix B Well-known Port NumbersRemote Console Troubleshooting Appendix C TroubleshootingPower/LED Status Troubleshooting Serial Console TroubleshootingTCP Server Mode Operation Troubleshooting IP Address TroubleshootingDhcp Troubleshooting Serial Communication Troubleshooting

LS100 specifications

The Senatek LS100 is a cutting-edge equipment designed to elevate operational efficiency across various industries. This innovative machine is widely recognized for its advanced features, which make it suitable for applications ranging from manufacturing to logistics.

One of the standout characteristics of the Senatek LS100 is its robust build quality. Constructed with durable materials, it is designed to withstand the rigors of heavy use, ensuring longevity and exceptional performance. The LS100 is engineered with precision to minimize maintenance requirements, which allows for uninterrupted workflow in demanding environments.

The LS100 is equipped with state-of-the-art technology that enhances its operational capabilities. At the core of its functionality is a powerful and efficient motor that allows for swift processing speeds. This ensures that tasks that would typically take hours can be completed in a fraction of the time, significantly boosting productivity.

A key feature of the Senatek LS100 is its user-friendly interface, which simplifies operation for users of all skill levels. Its intuitive controls and integrated software allow for easy adjustments and monitoring of tasks, making it easier for operators to focus on their core responsibilities without getting bogged down by complex machine handling.

With advanced safety features, the LS100 prioritizes the wellbeing of its operators. Safety protocols are embedded within its design, including automatic shut-off mechanisms and emergency stop options, which provide peace of mind while operating this high-performance equipment.

Additionally, the Senatek LS100 stands out for its energy efficiency. With rising energy costs, this machine is designed to consume less power without compromising performance, leading to lower operational costs over time. This eco-conscious design not only benefits businesses economically but also aligns with modern sustainability goals.

Versatility is another defining feature of the LS100. It can be customized with various attachments and upgrades, allowing it to adapt to a broad spectrum of tasks. Whether it's for assembly, packaging, or material handling, the LS100 can be tailored to meet specific operational needs.

In summary, the Senatek LS100 embodies the perfect blend of strength, innovation, and efficiency. Its durable construction, advanced technology, user-friendly interface, safety features, energy efficiency, and versatility make it an invaluable asset for businesses aiming to enhance their productivity and operational efficiency in today's competitive landscape.