DO RUNTIME CAL Screen
This lets you manually initiate a Runtime Calcu- lation test to calibrate the internal measurements which should result in more accurate runtime estimates. This only needs to be done once every 6 months, or if the load connected to the
�����������������
������������������
12
Note: Even when the screen saver is set to ‘ON’, the screen saver message will display only when the system load is less than 5%.
RESET TO DEFAULT: YES/NO Setting
This lets you force the unit to reset all previous set- tings to the factory default values. Use the Setup button to advance to this screen, then press either of the Up/Down Arrow buttons. The system display will first show INITIALIZING SETUP TO FACTORY DEFAULT and then INITIAL- IZATION COMPLETE once the process is complete. The system then returns to the RESET TO DEFAULT screen.
Troubleshooting
The VFD screen will display any faults or warn- ing conditions that occur along with a message explaining what action to take. If ever in doubt as to what action to take, please contact your authorised Rotel dealer or Rotel Technical Sup- port at
The RLC-1080 will not turn on
Possible Cause: Battery is not connected.
Solution: Remove front display panel by grasp- ing the sides and pulling straight back. The battery is located on the right side of the unit. The black battery connector should be pushed firmly into
DISPLY-BEEP TEST Screen�������������������
This forces the
Beep Tests. Use the Setup button to advance to the
the battery socket located just to the left of the battery pack. See the Connecting the Battery section of this manual to see a photograph.
Possible Cause: Input power cord is not
�������������������
������������������
Then press either of the Up/Down Arrow buttons. This will cause all indicators and display fields to light, and an audible beep to sound.
SCREEN SAVER: ON/OFF Screen
This lets you force the unit to alternate a message
����������������
������������������
Setting Default Screen
After one of the Status, Informational or Setup Screens have been displayed, the
connected properly.
Solution: Be sure the power cord is properly connected on both ends.
Possible Cause: No power or insufficient power available at the wall outlet.
Solution: Be sure the wall outlet is delivering the proper voltage by using a voltmeter. Or, if that is not possible, plug in a lamp to see if outlet has power. Note: The
Possible Cause: Circuit Breaker has tripped.
Solution: Check the circuit breaker on the rear panel of the