Uniden UBC 2500XLT manual Scann ing, Press Manual again

Page 25

Scann ing

1. Turn on the power, or press [SCAN] to start scanning.

Note: When the scanner is turned on, it is automati- cally in Scan Mode.

The indicators for the selected banks (1 through 20) appear on the display. The indicator of the bank currently being monitored flashes.

While the UBC 2500XL T is scanning, the "SCAN" message moves across the display. Scanning stops on any active channel automatically and displays its frequency, except those channels programmed with "UO" (Lock Out). Scanning resumes automatically after

the channel becomes inactive, unless DELAY is activated.

2. Deselect any bank(s) from being scanned by entering the number of the bank.

The deselected bank indicator(s) disappear from the display, and its channels will not be scanned. This procedure helps to speed up the scanning cycle.

Note: One bank must always remain active. You cannot deactivate all 20 banks at the same time.

Note: When you turn off the scanner and turn it back on, the previous bank selections will remain in effect.

To restore any bank for scanning, just enter its number again. I (The bank indicator will appear on the display.)

To stop scanning any time, press [MANUAL]. When you press [MANUAL] to stop scanning, you are out of Scan Mode. The scanner remains on the displayed channel, and only the bank indicator for that channel appears. If you press [MANUAL] again, you will step up a channel. If you press [LMT], you will step down a channel. Press and hold either key to rapidly step through the channels.

Note: You do not skip a locked out ("UG'? channel using any of these keys.

To start scanning again, press [SCAN].

To directly access a specific channel:

1.Press [MANUAL].

2.Enter the channel number using the numeric keys.

3.Press [MANUAL] again.

23

Image 25
Contents USC 2500XL T This equipment contains a Nickel-Cadmium PrecautionsTable of Contents About Your New UBC 2500XLT Leather-like Carrying Case UnpackingAuto Store Automatically stores all active frequencies Weather Channels Lets your scanner function as aAustralia TopView Controls and IndicatorsFrontView Scan KEY @ @4 Display. Note Youcannotdeactivateall20 banks LMTLIntKV Frequency. To store the same frequency into Send KEY Hold UO WX 1 2 KHz AM NFM WFM IkeylockiSetup Mounting the Flexible Antenna Installing the Belt ClipBank Scan If you have programmed channels, you Scanning OverviewBand Search The Search function is different from 0 5 Programming ChannelsThen, press Manual ProgrammingWith the Rotary Tuner If the selected channel already has a stored Frequency Example Set search limits of 137.000 to 144.000 MHz Ress Manual to stop scanningPress SRC to start the search HLD to stay on that frequencyPress Manual to stop scanning Auto Store feature automatically stores all activeFirst enter the lower limit by pressing 4 0 0 Press LMTDisplay. In this case, select another bank ~nother Open ChannelPress E Current channel is erased, and the display shows Deleting a Stored FrequencyPress Manual again Scann ingWeather Channel Scanning Customizing Scanner Operation Press Scan to start scanning This feature is active in Manual Mode or Scan ModeSetting Up Priority Channels To activate the Count feature Using Count to Monitor Channel ActivityTurn the scanner off before removing the Battery Pack Care and MaintenanceEvent of memory loss. If memory is lost, simply Reprogram each channelDo not use excessive amounts of water Clean the outside of the scanner with a mild detergentProblem TroubleshootingSearch Band Technical SpecificationsDisplay 137 174 222 400 520Warranty Unid~n~GP

UBC 2500XLT specifications

The Uniden UBC 2500XLT is a versatile and robust handheld scanner that has garnered a reputation among radio enthusiasts and professionals alike. Known for its advanced scanning capabilities, this model is designed to provide users with comprehensive access to various radio communications, making it an essential tool for both hobbyists and law enforcement personnel.

One of the standout features of the UBC 2500XLT is its wide frequency range. It is capable of tuning into VHF, UHF, and even some aircraft bands, covering a spectrum from 25 MHz to 1.3 GHz. This extensive range allows users to monitor an array of radio signals, including public safety communications, amateur radio, and other interesting transmissions.

The scanner employs Advanced Trunking Technology, enabling users to listen to trunked radio systems. This technology is crucial in modern communication systems, where multiple conversations can occur over a shared channel. The UBC 2500XLT can decode and track these trunked signals, ensuring that users do not miss important radio traffic.

Another notable characteristic of the UBC 2500XLT is its memory capacity. With 1000 memory channels available, users can store a significant amount of frequencies for quick access. It also features 10 banks for organizing these channels, helping users to categorize and manage their preferred frequencies efficiently.

Ease of use is another hallmark of the UBC 2500XLT. The scanner comes equipped with a large LCD display, providing clear visibility of the current frequency and other relevant information. The keypad is user-friendly, allowing for straightforward programming of channels and features. Additionally, the device includes a built-in scanner setup function, simplifying the process for beginners.

The UBC 2500XLT also boasts an impressive rechargeable battery, providing extended use without the need for frequent recharges. This aspect makes it ideal for outdoor activities or fieldwork, where access to power sources might be limited.

In summary, the Uniden UBC 2500XLT is a powerful handheld scanner that combines advanced technology with user-friendly features. Its wide frequency coverage, trunking capabilities, substantial memory, and ease of use make it a prime choice for anyone looking to explore the world of radio communications. Whether for hobby or professional use, the UBC 2500XLT stands out as a reliable tool in the scanner market.