Uniden BC355C owner manual Close Call Priority, Close Call Do Not Disturb, Close Call Only

Page 45

. Close Call Off

Pressing and holding the key acativates Close Call Only mode.

Close Call Priority

Repeatedly press until the Close Call Priority icon displays. The scanner checks every 2 second for a nearby transmission. You may hear a slight break in audio during this time. If you want to

monitor only Close Call hits, hold the key for longer than 2.5 seconds. The Close Call Priority icon flashes

Close Call Do Not Disturb

Repeatedly press until the Do Not Disturb icon displays. The scanner will periodically make Close Call checks whenever it is not receiving audio in another mode .

Close Call Only

Press and hold until the scanner displays a line of dashes and the icon flashes. The scanner is now in Close Call Only mode. It will only try to find Close Call transmissions. This is also the first step to accessing the Close Call Setup modes.

45

Image 45
Contents Scanner Patents Important InformationPage Table of Contents Special features Using Your BC355C ScannerLock Out Channels / Frequencies Temporary Lock Out Permanent Lock OutProgram Lock Feature FCC Wants YOU to Know Scanning Legally About Your NEW BC355C Scanner Feature Summary Canadian Marine Weather broadcasts Band Mode Steps Service MHz KHzFrequency Band Sensitivity Nominal 12 dB Sinad UHF TFrequency Band Close Call Sensitivity Nominal Frequency Band Hum and Noise NominalIncluded in Your Scanner Package Optional AccessoriesFor Home USE Desktop Installation Installing the BC355C ScannerFor Mobile Use In-Car Installation Temporary Mobile InstallationHelpful Hints Permanently Mounting the BC355C Unit Permanently Connecting the Mobile Power Supply BC355C Front Panel Scanner Operation OverviewUP and Down KEY Purpose HoldKEY Purpose PD/FD/EMG KEY Purpose AIR/MRN Close Call Nearby signals. Pressing this key cyclesThrough the frequencies in the following OrderSearch Programmable bank key Programmable bank key WX, orBC355C Rear Panel Using Your BC355C Scanner Set upAdjusting Squelch Scan Operating ModesSearch Special Notes for Scanning PD/FD/EMG and AIR/MRN Banks Scanning Service Bank Tips Here’s HowBefore you can scan it Hold Press this key to release Keep scanning after If the BC355C stops on an active UP/DOWN keys Searching Band Tips45.0600 148 ‐ Types of Lock Out Lock Out Channels / FrequenciesLock Out Limits Permanent Lock OutLock Out Tips Appears on the screen to indicate PRIVATE, PD/FD/EMG or AIR Preprogrammed channels Unlocked when you lock outEarliest channel will be More than 100 channelsClose Call Close Call Priority Close Call Do Not DisturbClose Call Only Setting Up Close Call Modes 800MHz Band Band Name Frequency MHzB1 LO on If You Want To Here’s How Found468.0000 Programming Frequencies and Channels 40.0600 000.0000 Deleting a Programmed Frequency programming CH 000.0000 flashing Police fire/emg Hold Program Lock Feature Problem Solution Troubleshooting GuideImproper Problem Solution Cleaning General Product CareLocation Technical Specifications RepairsBirdies Page Warrantor WarrantyDamaged or not maintained as reasonable or necessary Procedure for Obtaining Performance of Warranty Page Thank YOU for Purchasing a Uniden Product