Wasp Bar Code WWS850 Configuring your WWS800/850, Enter Configuration Mode, Default, List Setting

Page 21

10.Configuring your WWS800/850

The configuration of WWS800/850 Scanner is done by reading the setup labels contained in the Configuration Manual (the second part of this manual). This section describes the procedure of configuring the scanner. Some configuration examples are also given in this section for illustration.

10.1Enter Configuration Mode

To start the configuration, the “Enter Setup” label must be read. This will put the scanner in the configuration mode. The scanner will respond with 6 beeps and the indicator will turn blue after the label is read. This “Enter Setup” label is located at the bottom of almost every even page of the Configuration Manual.

10.2Default

All the parameters of the scanner will return to their default values by reading the “Default” label. The scanner will beep twice when the “Default” label is read.

10.3List Setting

The current setting of all scanner parameters can be sent to the host computer for user inspection. The listing is separated into ten pages. User can select the page of interest by reading the “Page x” label

Page 1: Interface, Buzzer, and Scanner Parameters

Page 2: Prefix, Postfix, and Length Code Setting

Page 3: Code ID

Page 4: Readable Symbologies

Page 5: Symbology Parameters (1/3)

Page 6: Symbology Parameters (2/3)

Page 7: Symbology Parameters (3/3)

Page 8: Editing Format 1

Page 9: Editing Format 2

Page 10: Editing Format 3

10.4Setting Parameter Values

For most of the parameters, only one read is required to set them to new values. The scanner will respond with two beeps when these parameters are configured. But for some special parameters, multiple reads are required to complete the setting. The scanner will respond with a short beep if the configuration of the parameter is still not complete. These parameters usually refer to a numeric value or a string of characters, such as keyboard type, inter-character delay, prefix / postfix code, etc..

For these kinds of parameters, the label of the parameter to be configured must be read first. Then the labels comprising the numeric value or character string are read. Finally, the “Validate” label must be read to complete the setting. The scanner will respond with two beeps when the “Validate” label is read.

10.4.1Numeric Parameters

The configuration procedures for numeric parameters are shown below.

Parameter Label

Decimal Label

"Validate" Label

For example, to configure the Inter-Character Delay to be 15 ms, the “Inter- Character Delay” label is first read, and then the decimal digit labels “1” and “5”, and finally, the “Validate” label to complete the setting.

10.4.2Character String Parameters

Basically, each character of a string is programmed by two hexadecimal digits, which usually comprise a value that is the ASCII code equivalence of the character being programmed.

Beside the two hexadecimal digits, there is an optional key type/status can also be specified for each character of the string parameters. This optional key type/status can only be specified for some particular parameters when keyboard interface is

35 36

Image 21
Contents User’s Manual Table of Contents Data Output Format Base Installation Power Up the Base StationIntroduction Setup RF Connection Power Up the WWS800/850Battery Charging your WWS800/850Interface Setting General FeaturesIndicator BuzzerSupported Symbologies Re-read DelayAuto-Sense Scanner Time-out DurationNegative Barcodes Output Interface Base UnitKeyboard Wedge Interface Keyboard Style AlphabetsRS232 Interface USB InterfaceMemory Parameters Configuring WWS800/850 Bluetooth Serial PortUpdate Settings Bluetooth HIDTimeout Activate Bluetooth HID InterfaceHID Keyboard Interface Reset ConnectionWindows XP with Service Pack2 Configuring Bluetooth Device DriverClick Find Bluetooth Devices icon at My Bluetooth Places Widcomm Bluetooth DriverCode39 Symbology ParametersItaly / French Pharmacode Industrial / Interleave / MatrixUpce CodabarEAN8 UpcaPlessey Telepen12 RSS Character Substitution Data Output FormatPrefix / Postfix Code Code IDData Editing Field Transmission Sequence Additional FieldsEnd of Format Programming Activate Data Editing FormatsEnter Configuration Mode Configuring your WWS800/850Default List SettingKey Type/Status Setting Exit Configuration Mode