Wasp Bar Code WWS850 Auto-Sense, Re-read Delay, Scanner Time-out Duration, Reading Redundancy

Page 7

Continuous Mode: The scanner is always scanning.

Auto Power Off Mode: The scanner will start scanning once the switch is triggered. The scanning continues until a preset scanning period (Scanner Time-Out Duration) is expired. Unlike the Auto Off mode, the scanner will continue to scan and the scanning period is re-counted each time there is a successful read.

Alternate Mode: The scanner will start scanning once the switch is triggered. The scanner will continue scanning until the switch is triggered again.

Momentary Mode: The scanner will be scanning as long as the switch is depressed.

Repeat Mode: The scanner is always scanning just like Continuous Mode. But now the switch acts like a “re-transmit button”. If the switch is triggered within 1 second after a good read, the same data will be transmitted again without actually reading the barcode. This “re-transmit button” can be triggered as many times as user desired, as long as the time between each triggering does not exceed 1 second. This scan mode is most useful when the same barcode is to be read many times.

Laser Mode: This scan mode is used on laser scanners. The scanner will scan once when the trigger is pressed. The scanning continues until a barcode is read, the trigger is released or a preset scanning period (Scanner Time-Out Duration) is expired.

Test Mode: The scanner is always scanning. The scanner will decode repeatedly even with the same barcode.

By default, the scan mode is Auto Off mode for scanners with trigger switch, and is Continuous mode for switch-less scanners.

3.4Auto-Sense

Auto-Sense is for WWS800 only and used in conjunction with the auto-sense stand. It will enable the scanner to start scanning once a barcode is brought within Range of the scanner. This will activate the LEDs and the scanner will start decoding the barcode. The auto-sense mode works only under Auto Off mode or Laser mode only.

3.5Re-read Delay

If the scanner mode is set to Continuous, Auto Power Off, Alternate, or Momentary mode, the scanner will prevent accidentally reading the same barcode twice by using a Re-read Delay (Blocking Time). The barcode must be taken away from the scanning line longer than the Re-read Delay to allow second reading of the same barcode. The user can set the Re-read Delay if necessary.

3.6Scanner Time-out Duration

This parameter is used to limit the maximum scanning period when the scan mode is either Auto Off Mode or Auto Power Off Mode. This time-out duration is specified in units of second. The default time-out duration is ten seconds.

3.7Reading Redundancy

This parameter is used to specify the levels of reading (decoding) security. If No Redundancy is selected, only one successful decoding can make the reading valid. If Three Times Redundancy is selected, it will take 3 successful decodes to make the reading valid. It is obvious that the more redundancy the user selects, the higher the reading security and thus the slower the reading speed. The user must compromise between decoding security and decoding speed if the security feature is needed.

3.8Supported Symbologies

Most of the popular barcode symbologies are supported. Each symbology can be individually enabled or disabled. The scanner will automatically discriminate and recognize all the symbologies that are enabled. The supported barcode symbologies are listed below.

Code 39 (Standard / Full ASCII)

Italy Pharmacode

French Pharmacode

Industrial 25

Interleave 25

Matrix 25

Codabar (NW-7)

UPCA (with or without Addon)

UPCE (with or without Addon)

7 8

Image 7
Contents User’s Manual Table of Contents Data Output Format Power Up the Base Station Base InstallationIntroduction Charging your WWS800/850 Power Up the WWS800/850Setup RF Connection BatteryBuzzer General FeaturesInterface Setting IndicatorScanner Time-out Duration Re-read DelaySupported Symbologies Auto-SenseKeyboard Style Alphabets Output Interface Base UnitNegative Barcodes Keyboard Wedge InterfaceUSB Interface RS232 InterfaceMemory Parameters Configuring WWS800/850 Bluetooth Serial PortActivate Bluetooth HID Interface Bluetooth HIDUpdate Settings TimeoutHID Keyboard Interface Reset ConnectionWindows XP with Service Pack2 Configuring Bluetooth Device DriverClick Find Bluetooth Devices icon at My Bluetooth Places Widcomm Bluetooth DriverIndustrial / Interleave / Matrix Symbology ParametersCode39 Italy / French PharmacodeUpca CodabarUpce EAN8Telepen Plessey12 RSS Code ID Data Output FormatCharacter Substitution Prefix / Postfix CodeData Editing Activate Data Editing Formats Additional FieldsField Transmission Sequence End of Format ProgrammingList Setting Configuring your WWS800/850Enter Configuration Mode DefaultKey Type/Status Setting Exit Configuration Mode