1.Warm up monitor for 15 minutes.
2.Input the small window pattern with 31KHz 640*480 mode.
3.Degauss the screen with Manual degaussing coil.
1.Remove the video signal.
2.Adjust the
1.Input the window pattern with 31KHz 640*480 mode.
2.Adjust the color temperature to be
3.Adjust step 2 until light output is 60FtL +/- 5FtL
4.Adjust “CO” to 3FtL +/- 2FtL for next step
5.Adjust the color temperature to be
6.Go back to OSD COLOR GAIN Factory Sub Menu and reset “CO” to MAX before returning to Main Factory Menu.
7.Exit Factory Menu by pressing “SEL” while in highlighted RESET position.
1.Purity Adjustment.
① Demagnetize the picture tube and cabinet using a degaussing coil.
② Turn the CONTRAST and BRIGHTNESS controls to maximum.
③ Adjust RED and BLUE bias controls to provide only a green raster. ④ Loosen the clamp screw holding the yoke and slide the yoke
backward to provide vertical green belt (zone) in the picture screen.
⑤Remote the Rubber wedges
⑥Rotate and spread the tabs of the purity magnet around the neck neck of
the
picture tube until the green belt is in the center of the screen. At the same time, center the raster vertically. Move the yoke slowly forward until a uniform green screen is obtained. Tighten the clamp screw of the yoke temporarily.
11