Wells-Gardner D9100 service manual Timing Chart, Description Mode

Page 6

4.TIMING CHART:

Factory Pre-Set Timing Modes.

Horizontal and Vertical Timing Diagram for Table 1.

TABLE 1 :

DESCRIPTION

MODE 1

MODE 2

MODE 3

MODE 4

VGA 720*400

VGA 640*480

8514/A 1024*768

S-VGA 680*480

 

 

 

FH

31.469KHz

31.469KHz

35.552KHz

37.500KHz

 

A

31.778µs

31.778µs

28.251µs

26.667µs

H

B

3.813µs

3.813µs

3.920µs

2.032µs

C

1.907µs

1.589µs

1.247µs

3.810µs

 

D

25.422µs

25.422µs

22.806µs

20.317µs

 

E

0.636µs

0.318µs

0.170µs

0.508µs

 

POL.

NEGATIVE

NEGATIVE

POSITIVE

NEGATIVE

 

FV

70.087Hz

59.940Hz

86.960Hz

75.000Hz

 

A

14.268ms

16.683ms

11.500ms

13.333ms

V

B

0.064ms

0.064ms

0.113ms

0.080ms

C

1.112ms

0.794ms

0.563ms

0.427ms

 

D

12.711ms

15.253ms

10.810ms

12.800ms

 

E

0.381ms

0.064ms

0.014ms

0.027ms

 

POL.

POSITIVE

NEGATIVE

POSITIVE

NEGATIVE

 

VIDEO

ANALOG

ANALOG

ANALOG

ANALOG

4

Image 6
Contents Printed on 02/11/04 Index Safety Precaution Specification Technical Features Timing Chart Description ModeDescription Mode 5, S-VGA Mode 7 VGA Page ② SEL Controls and Adjustments① MODE/EXIT ③ DOWN/UPPage Color Adjust Adjustment Specification Page Page Output MCU PIN Page Vertical section Page Page Troubleshooting No Video No Raster Trouble in Horizontal Size Trouble in Contrast Trouble in Brightness