Panasonic KX-TDA100 installation manual Optional Equipment, Model No Model Name Description, DHLC8

Page 23

1.3 Optional Equipment

1.3Optional Equipment

1.3.1Optional Equipment

Model No.

Model Name

Description

 

 

 

KX-TDA0103

L-Type Power Supply Unit (PSU-L)

Power Supply Unit for KX-TDA200. Total power

 

 

output of 279 W. Safety Class 1 compliant.

 

 

 

KX-TDA0104

M-Type Power Supply Unit (PSU-M)

Power Supply Unit for KX-TDA100 and KX-TDA200.

 

 

Total power output of 140.4 W. Safety Class 1

 

 

compliant.

 

 

 

KX-TDA0105

Memory Expansion Card (MEC)

Memory expansion card to increase system data

 

 

storage space, enable Broadcasting and Call Billing

 

 

for Guest Room features, and double the number of

 

 

DPTs, using Digital XDP connection. To be mounted

 

 

on the MPR card.

 

 

 

KX-TDA0108

S-Type Power Supply Unit (PSU-S)

Power Supply Unit for KX-TDA100. Total power

 

 

output of 74 W. Safety Class 1 compliant.

 

 

 

KX-TDA0143

4 Cell Station Interface Card (CSIF4)

4-port CS interface card for 4 CSs.

 

 

 

KX-TDA0144

8 Cell Station Interface Card (CSIF8)

8-port CS interface card for 8 CSs.

 

 

 

KX-TDA0161

4-Port Doorphone Card (DPH4)

4-port doorphone card for 4 doorphones and 4 door

 

 

openers. To be mounted on the OPB3 card.

 

 

 

KX-TDA0162

2-Port Doorphone Card (German

2-port doorphone card for 2 German-type

 

Type) (DPH2)

doorphones and 2 door openers. To be mounted on

 

 

the OPB3 card.

 

 

 

KX-TDA0164

4-Port External Input/Output Card

4-port external input/output card. To be mounted on

 

(EIO4)

the OPB3 card.

 

 

 

KX-TDA0166

16-Channel Echo Canceller Card

16-channel card for echo cancellation during

 

(ECHO16)

conferences. To be mounted on the OPB3 card.

 

 

 

KX-TDA0168

Extension Caller ID Card (EXT-CID)

Sends Caller ID signals to extension ports. To be

 

 

mounted on the SLC8 card only.

 

 

 

KX-TDA0170

8-Port Digital Hybrid Extension Card

8-port digital hybrid extension card for DPTs, APTs,

 

(DHLC8)

SLTs, DSS consoles, and PT-interface CSs, with 2

 

 

power failure transfer (PFT) ports.

 

 

 

KX-TDA0171

8-Port Digital Extension Card (DLC8)

8-port digital extension card for DPTs, DSS

 

 

consoles, and PT-interface CSs.

 

 

 

KX-TDA0172

16-Port Digital Extension Card

16-port digital extension card for DPTs, DSS

 

(DLC16)

consoles, and PT-interface CSs.

 

 

 

KX-TDA0173

8-Port Single Line Telephone

8-port extension card for SLTs with 2 power failure

 

Extension Card (SLC8)

transfer (PFT) ports.

 

 

 

KX-TDA0174

16-Port Single Line Telephone

16-port extension card for SLTs with 4 power failure

 

Extension Card (SLC16)

transfer (PFT) ports.

 

 

 

Installation Manual

23

Image 23
Contents Hybrid IP-PBX Installation ManualExtension Cards Main Processing CardMPR Option Card Trunk CardsPSUs Power Supply UnitsOptional SD Memory CardsAbbreviations in this manual Available Proprietary TelephonesImportant Safety Instructions Installation Manual For users in Germany only For business users in the European UnionFor users in Australia only For users in Finland, Norway and Sweden onlyFor users in New Zealand only Important NoticeFor Future Reference Installation Manual Trademarks Structure of this ManualAbout the Other Manuals About the software version of your Hybrid IP-PBXPrecautions for Users in the United Kingdom Installation Manual Table of Contents Connection of Extensions 136 Power Failure Connections 205Information about the Extension Cards 107 Information about the Other Cards 123220 212Connection 213 215Section System Outline System Highlights System HighlightsHospitality Features Portable Station PS FeaturesPC Phone/PC Console Features Construction of the Basic Shelf Basic System ConstructionBasic Shelf Hybrid IP-PBX System Connection DiagramDPT DHLC8 Optional EquipmentOptional Equipment Model No Model Name DescriptionPAY8 GW4E General Description SpecificationsMounted DimensionWeight when fully Extension Connection CableCharacteristics System Capacity Maximum Optional Service CardsCards Installed in the Slots of the Hybrid IP-PBX BRI8 PRI23 PRI30 IP-GW4 IP-GW4E Card Type Maximum Number Installed KX-TDA100 KX-TDA200MPR LCOT4 LCOT8 LCOT16 DID8 BRI4Card Type Maximum Number Mounted on KX-TDA100 KX-TDA200 Cards Mounted on Other Optional Service CardsCard Type Maximum Number APT IP-PT Maximum Terminal EquipmentEquipment Type MEC Figure MEC Card CalculationMEC Card Calculation Calculation Example KX-TDA100Equipment Type Load Figure Power Supply Unit SelectionLoad Figure Calculation PSU CapacityCalculation Example KX-TDA200 Specifications Section Installation Installation Precautions Before InstallationBefore Installation Safety Installation InstructionsBefore Installation KX-TDA100 KX-TDA200 Installation of the Hybrid IP-PBXUnpacking Inside View Names and LocationsOpening the Front Cover Opening/Closing the Front CoverClosing the Front Cover Accessories included Screws × Installing/Replacing the Power Supply UnitAccessories and User-supplied Items Safety InstructionsInstalling the Power Supply Unit Replacing the Power Supply Unit Replace the PSU Connect the frame of the Hybrid IP-PBX to earth Frame Earth ConnectionExamples Backup Battery ConnectionBackup Power Supply Duration User-supplied ItemsConnecting Backup Batteries Installing Optional Service Cards Installing/Removing the Optional Service CardsBack Board Release Lever Covering the Blank Slots Handling of the Cables Removing the Optional Service Cards BNC Types of ConnectorsConnector Type Pin Number Used for CTI-LINK KX-TDA0410MPR USB Attaching a Ferrite Core When connecting a T1/E1/PRI/IP-GW16/IP-EXT16 cardWhen connecting a BRI card When connecting an extension card Fastening Amphenol Connector LCOT4 LCOT8 LCOT16 DID8 DHLC8 DLC8 DLC16 MSLC16 SLC8 Amphenol Connector Pin Assignment ChartWall Mounting KX-TDA200 Installation of the Hybrid IP-PBX Wall Wall Mounting KX-TDA100Installation of the Hybrid IP-PBX Floor Standing KX-TDA200 Only TOP Front IP-PBX SLT PT Surge Protector InstallationInstallation OverviewIP-PBX Outside InstallationInstallation of an Earth Rod Installation of the Hybrid IP-PBX USB BGM/MOH Information about the Main Processing CardMPR Card Indication Colour Description Batt AlarmSD Access LED IndicationsMEC Card KX-TDA0105 RMT Card KX-TDA0196 LED Information about the Trunk CardsCard Status Amphenol ConnectorSignal Name Function Pin Assignments2 DID8 Card KX-TDA0182 LED Indications DIP Switch Settings on LCOT8/LCOT16 cardsSwitch Type Usage and Status Definition 3 CID/PAY8 Card KX-TDA01894 CID8 Card KX-TDA0193 5 E&M8 Card KX-TDA0184 SGB T1AR1A SGALED Indications 6 T1 Card KX-TDA0187 Switch SettingsSignal Name Level Function RJ45 Connector for Trunk UseRJ45 Connector for Extension Use Sync Maximum Cabling Distance of Extension ConnectionBNC RX 7 E1 Card KX-TDA0188BNC TX BNC coaxial Connector TX BNC coaxial Connector RX 8 BRI4 Card KX-TDA0284 and BRI8 Card KX-TDA0288 TX2 TX1RX2 RX1OFF Line LED PatternLine Master Clock LED PatternMaximum Cabling Distance of S0 Bus Connection 9 PRI30 Card KX-TDA0290CE/CJ Switch Settings Link Maximum Cabling Distance of Extension Connection 10 PRI23 Card KX-TDA0290 Pin Assignments Maximum Cabling Distance of Extension Connection IP-GW4 Card KX-TDA0480 RJ45 Connector 10BASE-TSignal Name Input I/Output O Function Data AlarmOnline IAM BusyIP-GW4E Card KX-TDA0484 RJ45 Connector 10BASE-T/100BASE-TXOFF IP-GW16 Card KX-TDA0490 LED Indications CSIF4 Card KX-TDA0143 and CSIF8 Card KX-TDA0144 Information about the Extension CardsPowl RJ45 ConnectorPowh DHLC8 Card KX-TDA0170 D1B D2AD1A D2BLED Indications 3 DLC8 Card KX-TDA0171 Data port 1 Low 4 DLC16 Card KX-TDA0172 D1J D2ID1I D2J5 SLC8 Card KX-TDA0173 Pin Assignments EXT-CID Card KX-TDA0168 7 SLC16 Card KX-TDA0174 and MSLC16 Card KX- TDA0175 Ring port Tip port 17-25 Reserved 42-50 IP-EXT16 Card KX-TDA0470 Online 1 OPB3 Card KX-TDA0190 Accessories included none User-supplied not included noneInformation about the Other Cards 2 DPH4 Card KX-TDA0161 User-supplied not included Copper wireDP2 Pin Terminal BlockDP4 DP33 DPH2 Card KX-TDA0162 Pin Assignments Path Doorphone Call Path 4 EIO4 Card KX-TDA0164 Pin Assignments External Relay Connection DiagramExternal Sensor ECHO16 Card KX-TDA0166 6 MSG4 Card KX-TDA0191 CTI-LINK Card KX-TDA0410 Link Status DSS Console Connection of ExtensionsPT-interface CS With DPT Using a Modular T-AdaptorParallel Connection of the Extensions With APTWith Other DPT except KX-T7560 and KX-T7565 Using an EXtra Device PortWith KX-T7600 Series DPT except KX-T7665 DptsltBack View of DPTs Digital EXtra Device Port Digital XDP ConnectionWith KX-T7600 Series DPT except KX-T7600E Series To TEL To Main Unit With KX-T7600E Series DPT Connecting to a Slave DPT Connecting to a Master DPT First Party Call Control CTI Connection CS Cell Station KX-TDA0142CE/KX-TDA0141CE RF SpecificationConnection of Dect Portable Stations OverviewEquipment Distance Conduct the site survey Procedure OverviewInvestigate the installation site Prepare for site surveyMount the CS on the wall Finish the site surveyUnderstanding Radio Waves Characteristics of Radio WavesSite Planning Object Material Transmission Tendency Site Survey Preparation Radio Signal Strength LevelsCS Coverage Area Things to take note Example Installing in a Room Separated by Interior WallsCS installation plan CS No Before Site SurveyChecking the CS ID Number Assigning the CS ID Number to the PSUsing the KX-TD7590 To enter letters DIP Switch Setting and Installing the CS Temporarily for Site SurveyFor users in the United Kingdom Testing the Radio Signal Strength Site Survey Using the KX-TCA255/KX-TD7590PS CH0 Channel no Clearing the Stored Scan Data Using the KX-TD7590 Log NoReferring to the Stored Scan Data After Site Survey User-supplied not included RJ11 connector Connecting a Cell Station to the Hybrid IP-PBXUsing a Csif Card Accessories and User-supplied Items for the CSUsing a DHLC/DLC Card Connecting the CS For the KX-TDA0142CE User only PS Registration Administrator LevelUsing the KX-TCA155/KX-TCA255 Registering the PSUsing the KX-TD7580 System Lock PasswordSystem Lock Password /OK Changing the Display Language of the PS Setting the PIN for Hybrid IP-PBXHandset PIN 691PS Termination Testing the Operation Wall Mounting Reference for Wall Mounting Install a screw here 71 mmCS Cell Station KX-TDA0142/KX-TDA0141 KX-TDA0142 Using a Csif CardKX-TDA0141 Using a DHLC/DLC Card Connection of 2.4 GHz Portable StationsConnection of 2.4 GHz Portable Stations Prepare the CS for site survey Using the KX-TD7680Using the KX-TD7690 Finish the site survey Site Planning Object Material Transmission Tendency CS Coverage Area Example Installing in a Room Separated by Interior Walls CS Number Switch Radio Signal Test Switch CS no CS no CS no Connection of 2.4 GHz Portable Stations Scan Data No Site SurveyPS CS NO.1 LEVEL12 Scan Data No Deleting the Stored Scan Data After Site Survey Connecting a Cell Station to the Hybrid IP-PBX Using a DHLC/DLC Card Connecting the CS System Setting Menu Entering the System Programming ModePT Administrator Level PS Using the KX-TD7680When the PS has not been registered yet Setting the System Lock 692 Setting the PIN for PS Using the KX-TD7680System Wall Mounting Reference for Wall Mounting Maximum Cabling Distance Installing the Doorphone KX-T30865Connection Installation Manual BGM Connection of PeripheralsConnection of Peripherals Pin Assignments Connection ChartsPager PC/Printer via RS-232CReceive Data RXD…input For connecting a printer/PC with a 25-pin RS-232C connectorRS-232C Signals Signal Ground SGUSB D+ PC/CTI Server via USB versionVbus USB DUsing Analogue Trunk Card and Extension Card Power Failure ConnectionsPower Failure Connections PFT Ports 3 and 4 for LCOT16 card only Signal Name Function RJ11 Connector Pin Assignments for Analogue Trunk CardRJ11 Connector Pin Assignments for Extension Card PFT Ports 1 Signal Name FunctionRJ45 Connector Line 1 Pin Assignments Using BRI CardSwitch Settings RJ45 Connector Line 2 Pin Assignments Starting the Hybrid IP-PBX Starting the Hybrid IP-PBXRUN Confirming the Trunk ConnectionSection Guide for the KX-TDA Maintenance Console Overview KX-TDA Maintenance Console*1LAN Connection via CTI-LINK Card ConnectionConnection Serial Interface ConnectionSD TXD RD RXD DR DSR ER DTR External Modem ConnectionSystem Requirements Installation of the KX-TDA Maintenance ConsoleInstalling and Starting the KX-TDA Maintenance Console Password SecurityStart the KX-TDA Maintenance Console from the Start menu Installing the KX-TDA Maintenance ConsoleWhen country/area data do not match Installation of the KX-TDA Maintenance Console Section Troubleshooting Installation TroubleshootingProblem Probable Cause Solution Cause Trunk is connected to the T2/R1 Operation Problem Probable Cause Solution Operation Using the Reset ButtonDescription Troubleshooting by Error LogError Log Display Format Description BRI, PRI, OPB3, E&M, IP List of Errors and SolutionsError Code Error Message SLC, CSIF, LCOT, T1, E1System Start-up and On-line Operation Probable Cause Solution Probable Cause Solution RAM NG IP-GW, DID, SLC8, IP ROM NGCSIF, T1, E1, BRI, PRI OPB3, CTI-LINK, E&MMPR-LPR CSIF, T1, E1, BRI, PRI IP-GW Dpram IP-GW SdramIP-PT SUB-CPU Probable Cause Solution Probable Cause Solution Section Appendix Pmpr Software File Version New ContentsChanged Contents Revision HistoryPmpr Software File Version Pmpr Software File Version Index Numerics PSU PSU-L PSU-M PSU-S Index 62, 4-chome, Minoshima, Hakata-ku, Fukuoka 812-8531, Japan
Related manuals
Manual 194 pages 61.97 Kb Manual 282 pages 61.74 Kb Manual 40 pages 36.33 Kb Manual 58 pages 2.3 Kb Manual 194 pages 61.15 Kb

KX-TDA100 specifications

The Panasonic KX-TDA100 is a versatile digital hybrid telephone system designed to meet the communication needs of small to medium-sized businesses. This system blends traditional telephone functions with advanced digital technology, making it an excellent choice for organizations looking to enhance their telecommunications infrastructure.

One of the key features of the KX-TDA100 is its ability to support both digital and analog telephony, allowing businesses to integrate existing telephone lines and devices with newer technologies. The system can accommodate up to 100 extensions, making it scalable and suitable for growing businesses. Additionally, it supports a variety of communication services, including voice mail, computer telephony integration, and automatic call distribution, which enhances customer service capabilities.

The KX-TDA100 utilizes advanced digital signal processing technology, ensuring clear and reliable communication. It employs features such as call forwarding, caller ID, call waiting, and conference calling, which improve productivity and streamline communication among team members. The system also allows for the integration of mobile devices through its support for SIP trunking, enabling seamless communication even when employees are on the go.

Furthermore, the KX-TDA100 includes built-in voicemail functionality, allowing businesses to manage messages efficiently. The voicemail system supports features like voicemail-to-email, which provides users with immediate access to their messages, and the option to customize greetings and auto-attendants that enhance caller experiences.

Security is another critical aspect of the KX-TDA100. The system offers various security features to protect against unauthorized access and ensure data integrity, including encryption and secure network protocols. This attention to security makes it suitable for businesses that handle sensitive information.

Overall, the Panasonic KX-TDA100 combines flexibility, scalability, and advanced technology, making it an ideal solution for businesses looking to improve their communication systems. Its user-friendly design, robust feature set, and ability to grow with the organization make it a reliable choice for enhancing productivity and ensuring effective communication within teams and with customers. Whether deploying for day-to-day operations or accommodating remote work, the KX-TDA100 offers the reliability and features that modern businesses require.