Maintenance
TEMP and LAMP Indicators
Managing the indicated problems
If a problem should occur with the projector, the LAMP and/or TEMP indicators will inform you. Manage the indicated problems as follows.
111 Confirm the status of all indicators and projector, and switch off
the projector in proper way.
222 Find out the cause of the problem by status of the LAMP and/
| or TEMP indicators. | Power LAMP TEMP | |
333 | Follow the following instruction for each indication and solve | ||
| |||
| the problem. |
| |
444 | Turn on the projector in the correct way and confirm the |
| |
| indicator is not indicating a problem any longer. |
|
JJ TEMP indicator
| Illuminating red while projecting and the alert will be displayed. |
| |||
Indicator | Flashing red and the power button is turned off automatically. |
| |||
When the TEMP indicator is lit, the lamp might have darkened. |
| ||||
|
| ||||
| Adjustments can be performed but not all changes will be shown on the image. |
| |||
Problem | The temperature inside and/or outside the projector is abnormally high. |
| |||
Cause | The air intake and exhaust | The room temperature is | The air filter is excessively |
| The projector is located |
dirty and the ventilation is |
| at high elevations (above | |||
ports are covered. | too high. |
| |||
| poor. |
| 1 400 - 2 700 m). | ||
|
|
|
| ||
|
|
|
|
| Turn on the projector and |
| Remove the object(s) |
|
|
| set the HIGH ALTITUDE |
| Reinstall the projector in | Clean or replace the air |
| MODE to ON. | |
Remedy | from the ventilation |
| |||
a temperature controlled | filter in the proper method. |
| See “INSTALLATION” of | ||
openings or clear around |
| ||||
| place. See page 32. | See page 26. |
| the functional instructions | |
| the projector. |
| |||
|
|
|
| that is in the provided CD- | |
|
|
|
|
| |
|
|
|
|
| ROM. |
JJ LAMP indicator
Indicator | Illuminating red | Flashing red |
|
| |
Problem | LAMP RUNTIME has | Lamp circuit failure, abnormal function or lamp unit is damaged. | |||
reached 1 800 hours. | |||||
|
|
|
| ||
Cause | The lamp unit will run out | The power is turned on | Lamp circuit failure, |
| |
soon and needs to be | again before the lamp unit | The lamp unit is damaged. | |||
| replaced. | is cooled enough. | abnormal function. |
| |
|
|
| |||
Remedy | See “Replacing the lamp | Let the lamp unit cool | Contact an Authorized | See “Replacing the lamp | |
down and turn on the | |||||
unit” on page 27. | Service Center. | unit” on page 27. | |||
| power after 90 seconds. | ||||
|
|
|
|
|
|
|
NOTE: |
| Maintenance |
•• If no problem is found or the problem remains, do not turn on the projector. Instead contact an Authorized Service Center. |
| |
|
| |
|
|
|