LAMP, TEMP and FILTER Indicators
Managing the indicated problems
If a problem should occur with the projector, the LAMP, TEMP and/or |
| |
FILTER indicators will inform you. Manage the indicated problems as |
| |
follow. |
| |
1. | Confirm the status of all indicators and projector, and switch off the |
|
| projector in proper way. |
|
2. | Find out the cause of the problem by status of the LAMP, TEMP | POWER LAMP TEMP FILTER |
| and/or FILTER indicators. | |
3. | Follow the instruction for each indication below and solve the |
|
| problem. |
|
4.Turn on the projector in the correct way and confirm the indicator is not indicating a problem any longer.
NOTE:
• If no problem is found or the problem remains, do not turn on the projector. Instead contact an Authorised Service Centre.
LAMP indicator
Indicator | Illuminating RED | Flashing RED |
|
| |
|
|
|
|
| |
Problem | LAMP RUNTIME has | LAMP circuit failure, abnormal function or Lamp unit is damaged. | |||
reached 4 800 hours. | |||||
|
|
|
| ||
| Lamp unit will run out | The MAIN POWER is |
|
| |
Cause | switched on again before | LAMP circuit failure, |
| ||
soon and needs to be | Lamp unit is damaged. | ||||
the Lamp unit is cooled | abnormal function. | ||||
| replaced. |
| |||
| enough. |
|
| ||
|
|
|
| ||
|
| Let the Lamp unit cool |
|
| |
Remedy | See “Replacing the Lamp | down and turn on the | Contact an Authorised | See “Replacing the Lamp | |
unit” on page 43. | MAIN POWER after | Service Centre. | unit” on page 43. | ||
| |||||
|
| 90 seconds.. |
|
| |
|
|
|
|
|
TEMP indicator
Indicator | Illuminating RED while projecting and the alert will be displayed. |
| |||
Flashing RED and POWER is turned off |
|
| |||
|
|
| |||
Problem | The temperature inside and/or outside the projector is abnormally high. |
| |||
|
|
|
|
| |
Cause | The ventilation openings | The room temperature is | The ARF is excessively | The projector is located at | |
dirty and the ventilation is | 1 400 - 2 700 m (4 593 - | ||||
are covered. | too high. | ||||
| poor. | 8 858 ft). | |||
|
|
| |||
| Remove the object(s) | Reinstall the projector in | Replace the ARF in the | Turn on the projector*1 | |
Remedy | from the ventilation | ||||
temperature controlled | proper method. See | and set the ALTITUDE to | |||
openings or clear around | |||||
| place. See page 50. | page 42. | HIGH. See page 37. | ||
| the projector. | ||||
|
|
|
| ||
|
|
|
|
|
*1. The projector will perform only 2 minutes with OFF setting at high elevation.
FILTER indicator
When the FILTER indicator is flashing GREEN, the ARF is normally rolling up.
Indicator | Illuminating RED | Flashing RED | Illuminating ORANGE | Flashing ORANGE | |
|
|
|
|
| |
Problem | FILTER REMAINING has | The projector cannot | The ARF cannot operate | FILTER REMAINING has | |
turned yellow. See | |||||
turned red. See page 36. | detect the ARF. | properly. | |||
| page 36. | ||||
|
|
|
| ||
Cause |
|
| Foreign object is blocking | ARF is running out and | |
ARF has been run out. | ARF is not attached. | the remaining time is | |||
|
|
| the ARF operation. | about 240 hours.. | |
|
|
|
| ||
| See “Replacing the ARF |
| Remove the foreign |
| |
Remedy |
| object or contact an | Prepare the ARF for | ||
(Auto Rolling Filter)” on | Attach the ARF. | ||||
Authorised Service | replacement. | ||||
| page 42. |
| |||
|
| Centre. |
| ||
|
|
|
| ||
|
|
|
|
|
Maintenance