Zebra Technologies P120i user manual Declarations of Conformity, Tte

Page 6

Foreword

Return Materials Authorization

Declarations of Conformity

 

 

 

 

 

 

 

89/336/EEC

EMC Directive

EN 55022 (1998)

RF Emissions control

 

 

 

 

 

 

 

EMC Directive

EN 301489-3

RF Emissions and Immunity for

 

 

modified by

 

 

 

V1.4.1

radio equipment

 

 

92/31/EEC and

 

 

 

 

 

 

 

 

93/68/EEC

EMC Directive

EN55024

Immunity to Electro-Magnetic

 

 

 

 

(2001)

Disturbances

 

 

73/23/EEC

 

EN 60950-1

Product safety

 

 

modified by

Low voltage Directive

(2001)

 

 

 

93/68/EEC

 

 

 

 

 

1999/5/CE

R&TTE

EN300330-2 V1.1.1

Radio Frequency Interferences

 

 

Directive

 

 

 

 

 

 

 

 

 

 

 

 

 

For a formal certificate, please contact the Compliance Office at Zebra’s Camarillo facility.

EUROPE: Norway Only: This product is also designed for IT power system with phase to phase voltage 230V. Earth grounding is via the polarized, 3-wire power cord.

FI: “Laite on liitettävä suojamaadoitus koskettimilla varustettuun pistorasiaan”

SE: “Apparaten skall anslutas till jordat uttag”

NO: “Apparatet må tilkoples jordet stikkontakt”

Model P120i conforms to the following specification: FCC Part 15, Subpart A, Section 15.107(a) and Section 15.109(a) Class B digital device.

Supplemental Information

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference’s by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and the receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

The user may find the following booklet, prepared by the Federal Communications Commission, helpful:

How to identify and resolve Radio/TV Interference Problems. This booklet is available from the U.S. Government printing Office, Washington, D.C. 20402, Stock No. 004-000-00345-4. Use of a shielded cable is required to comply within Class B limits of Part 15 of FCC Rules. Pursuant to Part 15.21 of the FCC Rules, any changes or modifications to this equipment not expressly approved by Zebra may cause, harmful interference and void the FCC authorization to operate this equipment.

iv

P120i Card Printer User Guide

980504-001 Rev. A

Image 6
Contents User’s Manual Page Copyright Notice TrademarksPrintheads Warranty InformationPrinters Spare PartsReturn Materials Authorization Product DisposalDeclarations of Conformity TTEP120i Printer Model Part Number DescriptionIcons Contents P120i Printer Operation Getting Started Unpacking Your Card PrinterControls and Indicators Power SwitchPower Socket USB Port Multi-Function LCD PanelPrinting Mono Printer Installation Installing the P120i PrinterPrint Driver Installation From the Main Menu, select Install Printer DriverPrinter Installation Printer Installation USB Installation From the Select the Setup Type windowCustom Installation From the Network Printer Components window Printer Installation Printer Installation Encoder Settings Printer Installation Printer Installation Printer Installation Ethernet Installation Printer Installation Printer Installation Printer Installation Printer Installation Printer Installation Printer Installation Printer Installation Printer Installation Complete Printer Installation P120i printerConnect the P120i Printer 115 VAC 230 VAC Page Printer Installation 980504-001 Rev. a Printer Installation Change Printer Driver Options Printer Installation Printer Installation Printer Installation Page P120i Printer Setup Printer FeaturesLoading Ribbon Cartridge Loading Cards Card FeederCard Feeder Cover Stack Printing a Test Card Card Output HopperPage P120i Printer Operation PrintingCreating a Sample Card Printing a Sample Card P120i Printer Operation Page When to Clean CleaningCleaning System How to CleanCleaning Cleaning the Print Head Page Troubleshooting Troubleshooting ProceduresPrint Quality Issues Possible Cause Ribbon cartridge may not be correctly positioned Page Technical Specifications USB 1.1 cable included Card Dimensions ISO standard dimensions for plain cardISO standard dimensions for magnetic stripe card Page Magnetic Card Stripe Encoder IntroductionMedia Loading Orientation Magnetic Encoder Cleaning ISO Standard EncodingCard SenseTM Single Card Feed Mode Printing a Single Card Without Using the FeederInstall Card SenseTMSingle Card Feed Kit Install Card Cleaning Cartridge Setting Up the Printer Driver Printing a Single Card Page Zebra Technologies Corporation