Pass Labs X5 owner manual For your protection please read the following

Page 9

For your protection please read the following:

X5 Owner’s Manual

Water and moisture: Electrical devices should not be used near water ( as per example, near a bathtub, washbasin, kitchen sink, laundry tub, wet basement or swimming pool ). Care should be taken such that objects do not have the opportunity to fall, and that liquid is never spilled onto or into the device enclosure through openings.

Power Sources: An electrical device must be connected to a mains power source in strict accordance with the supplied product owner’s manual. Please verify that the AC mains voltage specified in the product manual matches those requirements indicated on the unit and the AC voltage provided to your location by the power company.

Grounding: Adequate precautions should be taken so that the grounding provisions built into an electrical product are never defeated.

Power Cords: Pass Laboratories provides a power supply cord that meets all legislated requirements for the market in which the product was originally sold. If you choose to substitute an after-market product we urge you to choose one that is fully safety rated by the necessary local authority.

Power Cord Protection: Power supply cords should be routed so that they are not likely to be walked on, abraded, or pinched by items placed on or against them, paying particular attention to cords where they enter plugs or exit from a device. Never under any circumstance insert a cut or damaged power cord into a mains power socket.

Power and Signal: Cables should never be connected / disconnected with equipment powered up. Failure to heed this warning may damage or destroy equipment.

Ventilation: Power-amplifiers run hot, but you should be able to place your hands on them without discomfort. You must allow for this heat in installation, by providing for free air circulation around the product. Electronics should not be subjected to sources of excessive radiant heat. Excessive heat can shorten the life of the product and may cause the electronics to self-protect and shut down.

Servicing: To reduce the risk of fire, electrical shock or other injuries, the user should not attempt to service the device beyond that which is described in the operating instructions. All other servicing must be referred to qualified service personnel.

9

Image 9
Contents PassTM Introduction Setup Page Speaker Interface Fun Hardware Facts X5 Specifications Warranty Information For your protection please read the following

X5 specifications

Pass Labs X5 is a distinguished power amplifier that brings together advanced engineering with a commitment to high-fidelity sound reproduction. Designed for audiophiles who desire an extraordinary listening experience, the X5 is a testament to the brand’s dedication to quality and performance.

At the heart of the X5 is its balanced Class A topology, which ensures that the amplifier delivers a rich sound signature with a lush midrange and extended high frequencies. This configuration minimizes crossover distortion, providing a clean and accurate representation of the input signal. The result is a dynamic range that captures the subtleties in music, from the softest whispers to the most powerful crescendos.

The X5 boasts a powerful output stage capable of delivering 300 watts per channel into 8 ohms, making it suitable for driving a wide range of speakers with ease. This power allows the X5 to maintain control over the speakers, ensuring that even during demanding passages, there is no loss of clarity or detail. The amplifier's ability to handle low impedance loads further enhances its versatility, catering to a vast array of speaker types.

One of the standout features of the Pass Labs X5 is its dual-mono architecture. This design isolates the left and right channels, reducing crosstalk and enhancing stereo imaging. By keeping the signal paths dedicated, listeners can enjoy a more defined soundstage where each instrument and vocal can be placed exactly where it was intended in the mix.

The build quality of the X5 is exceptional, with a robust chassis designed to minimize vibrations and interference. The internal components, including high-quality capacitors and resistors, are meticulously selected to optimize performance and longevity. The attention to detail extends to the heat sink design, which ensures efficient thermal management, keeping the amplifier cool during long listening sessions.

Overall, the Pass Labs X5 power amplifier represents the pinnacle of audio engineering, combining innovative technologies with a robust design to deliver unparalleled sound quality. Whether used in a dedicated listening room or as part of a high-end home theater system, the X5 stands as a premier choice for those who seek the ultimate in audiophile performance. With its impressive power, precision, and beauty, the X5 is not just an amplifier; it is an investment in musical enjoyment for years to come.