Table 2 lists the most common cable and connector combinations for the 10BASE-FL media adapter, assuming the maximum permitted attenuation with ST connectors. The table lists the maximum (total) distance allowed in the fiber connection. However, your fiber connection may have to be shorter to meet the optical power budget and Ethernet repeater rules.

Table 2. 10BASE-FL cable and connector combinations

Number of in-line

62.5/125-m

50/125-m

fiber-to-fiber

cable

cable

connections

 

 

 

 

 

0

2000 m (6560 ft)

2000 m (6560 ft)

1

2000 m (6560 ft)

2000 m (6560 ft)

2

2000 m (6560 ft)

2000 m (6560 ft)

3

2000 m (6560 ft)

1710 m (5620 ft)

4

2000 m (6560 ft)

1430 m (4690 ft)

5

2000 m (6560 ft)

1140 m (3750 ft)

6

1750 m (5740 ft)

860 m (2810 ft)

7

1500 m (4920 ft)

570 m (1870 ft)

8

1250 m (4100 ft)

290 m (940 ft)

9

1000 m (3280 ft)

0

10

750 m (2460 ft)

 

11

500 m (1640 ft)

 

12

250 m (820 ft)

 

13

0

 

 

 

 

893-862-B

5

Image 7
Contents Using the BayStack Ethernet Fiber Media Adapters Ordering Bay Networks Publications TrademarksStatement of Conditions Related PublicationsIntroduction 10BASE-FL BayStack 10BASE-FL Media AdapterSingle Mode Fiber BayStack Single Mode Fiber Media AdapterFiber Optic Cable Length Limitations BASE-FL Optical power budget Parameter 62.5/125 ∝m893-862-B Single-mode fiber optical power budget Parameter 125 ∝m BayStack Single Mode Fiber Media AdapterMake appropriate cable connections Installing a Media Adapter in a BayStack HubMedia adapter status LEDs Hub media Adapter LEDs Verify the installation for the media adapterBay Networks, Inc. One-year Limited Hardware Warranty Bay Networks Customer Support Electromagnetic Emissions