Aube Technologies PB1 30-024T Introduction, Configure the Switch, Install the Control Module

Page 2

Regulator TH1 31 -R

User Guide

C o n tro l M o d u l e

Heating

Command

Indicator Light

ON/OFF

Switch

Power Selection Dial

Introduction

Thank you for choosing Aube’s TH131-R regulator.

The TH131-R is specially designed to control an electric floor heating installation, a baseboard or a convector.

The TH131-R regulator operates like a dimmer switch to allow you to easily adjust the amount of power sent to your heating system.

This control module can be used with a line voltage power base (230 V European models) or a low voltage power base (24 V) combined with an electromechanical or triac relay.

Configure the Switch

Located in the lower-right corner of the control module, this switch is used to select the heating cycle based on the power base.

230 V LINE VOLTAGE BASE

￿ALWAYS 15 minutes

24 V LOW VOLTAGE BASE

15 MIN

Use with a triac or electromechanical relay. Recommended for mechanical actuated system (water heating using a solenoid valve, etc.) or a fan-forced heater.

15 SEC

Use only for installations with SSR TRIAC relay. Recommended for electric heating (baseboards, convectors, etc.).

The TH131-R is equipped with an ON/OFF switch making it possible to turn off the regulator when its use is not required (e.g. summer).

Install the Control Module

Align the bracket tabs on the control module with the holes located on the power base and secure using the screw.

Control Module

Air Vents

 

Air Vents

Power Base

NOTE: Keep the regulator’s air vents clean and free from obstructions.

NOTE: The screw cannot be removed completely.

Operation

Technical Specifications

Warranty

Service

The TH131-R regulator operates on perpetual 15-minute or 15-second heating cycles.

For example (15-minute cycles), if the dial is set halfway, the system will

heat for 50% of the cycle; it will be ON

for 7.5 minutes and OFF for 7.5 minutes.

Below is a detailed table of the cycle duration based on the dial’s position:

Position and

I

2

4

6

8

10

equivalent %

0%

20%

40%

60%

80%

100%

 

 

 

 

 

 

 

ON

0 min

3 min

6 min

9 min

12 min

15 min

OFF

15 min

12 min

9 min

6 min

3 min

0 min

 

 

 

 

 

 

 

NOTE: Depending on the power base used, the heating cycles can be 15 seconds or 15 minutes.

Model: TH131-R

Setting Range: from 0 to 100%

Storage: -4°F to 120°F (-20°C to 50°C)

Heating cycles: 15-minute or 15-second

Size (H/W/D): 3,1 x 3,1 x 0,64 in. (78,9 x 78,9 x 16,3 mm)

Available Relays

Electric Heating Solid State Relay:

RT850 this model handles 100 to 347 V.

RT850T this model has a built-in 24 V transformer and is available in 240, 277 and 347 V.

Electric Heating Electromechanical Relays:

RC840 this model handles 120 to 347 V.

RC840T this model has a built-in 24 V transformer and is available in 240, 277 and 347 V.

AUBE TECHNOLOGIES INC. TWO (2) YEAR LIMITED WARRANTY

This product is guaranteed against workmanship defects for a two-year period following the initial date of purchase.

During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions.

The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation.

This warranty cancels and replaces any other manufac- turer's express or implied warranty as well as any other company commitment. AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product.

The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, pre- paid and insured, to the nearest address.

If you have any questions concerning the TH131-R regulator, call our technical support team at:

705 Montrichard

10 rue Ampère

Saint-Jean-sur-Richelieu

95500 Gonesse

(Quebec) Canada

France

J2X 5K8

 

 

Tel.:

(450) 358-4600

33 (0) 1 34 07 99 00

 

1-800-831-AUBE

33 (0) 1 34 07 99 19

Fax:

(450) 358-4650

 

service@aubetech.com

advaube@comintes.com

For more information on our products, visit us at

www.aubetech.com

19/12/03 400-131-008-A

Image 2
Contents Technical Specifications Installation GuidelinesInstallation Steps IntroductionOperation Technical Specifications Warranty Configure the SwitchInstall the Control Module Introduction