Toshiba 1600EP Series UPS Specifications, Standard Models 3.6kVA-RoHS 3.6kVA 6kVA 8kVA, 3.1 kW1

Models: 1600EP Series

1 64
Download 64 pages 52.93 Kb
Page 23
Image 23
UPS Specifications

UPS Specifications

Standard Models: 3.6kVA-RoHS; 3.6kVA; 6kVA; 8kVA

Unit (Capacity)

3.6 kVA-RoHS

 

3.6 kVA (3.1 kW)1

6 kVA (5.1 kW)1

8 kVA (6.8 kW)1

(3.1 kW)1

 

 

 

 

 

 

 

 

 

General

 

 

 

 

 

 

 

Topology

 

 

 

True On-line

 

Certifications

 

 

 

UL, CUL, ISO 9001, NEMA/PE1-1993

 

Input Characteristics

 

 

 

 

 

 

 

Input Voltage

 

 

Single-phase, 208/240 Vac, -30% – +10%

 

Input Frequency

 

 

 

45 – 65 Hz (auto-sensing)

 

Input Capacity

 

3.6 kVA

 

6.0 kVA

8.0 kVA

Input Power Factor

 

 

 

> 0.95 for all loads

 

Current THD (linear load)

 

 

 

< 5% total harmonic distortion

 

Included AC Input Breaker

 

30 A/277 V

 

50 A/277 V

60 A/277 V

Rating

 

 

 

 

 

 

 

 

 

Battery Characteristics

 

 

 

 

 

 

 

Battery Type

 

 

Valve Regulated Lead Acid, Flame Retardant

 

Backup time, fully charged

8 min.

 

 

14 min.

 

7 min.

@ 0.7 power factor, 77 °F

minimum2

 

 

minimum2

 

minimum2

Backup time, fully charged

7 min.

 

 

10 min.

 

7 min.

@ 0.85 power factor, 77 °F

minimum2

 

 

minimum2

 

minimum2

Recharge Time

 

24 hr. (full), 12 hr. (90%) for internal batteries only3

Battery Voltage (Nominal)

144 Vdc

 

 

216 Vdc

 

216 Vdc

288 Vdc

Output Characteristics

 

 

 

 

 

 

 

Output Voltage

 

 

 

Single-phase, 240/208/120 V

 

Output Voltage Regulation

 

 

± 3%

 

 

Output Frequency

±0.5 Hz/1 Hz/1.5 Hz (factory or authorized service center selectable only)

AUTO/MAN Frequency

Factory or authorized service center selectable only

Voltage THD

 

 

< 3% for linear load; < 6% for non-linear load

 

Common-Mode Noise

 

 

 

< 0.5 Vrms

 

Rated Load Power Factor

 

 

 

0.85 (0.6 – 1.0) lagging

 

Efficiency (ac-dc-ac)

 

 

 

> than 83% (without battery charge)

 

Voltage Transient

 

 

 

< ±8% (Load of 0 – 100 %)

 

Rated Output Current (rms)

 

 

15 A

 

25 A

33.3 A

Max. Peak Output Current

 

 

45 A

 

75 A

100 A

Inverter Overload Capacity

 

 

 

125% for 30 sec./150% for 10 sec.

 

Bypass Overload Capacity

 

 

 

125% for 10 min./1000% for 1 cycle

 

Crest Factor

 

 

3.0

 

 

1.Input/output figures rated for 240 volts. Output ratings given for 0.85PF are only valid when the input voltage is greater than 204 volts; otherwise, ratings given for 0.70PF are applicable.

2.Battery backup time may vary depending on the operating conditions and ambient temperature at the installation site.

3.An initial charge time of 24 hrs. is necessary to obtain proper battery performance level before unit is placed in operation.

1600EP Series Instruction Manual

15

Page 23
Image 23
Toshiba 1600EP Series manual UPS Specifications, Standard Models 3.6kVA-RoHS 3.6kVA 6kVA 8kVA, Unit Capacity, kVA 3.1 kW1