Installation Precautions

Caution

1.Install the unit in a well-ventilated location; allow at least 4 inches (10 cm) on all sides for air ventilation and for maintenance.

2.Install the unit in a stable, level and upright position that is free of excessive vibration.

3.Install the unit where the ambient temperature is within the range specified on pages 16 and 19.

4.DO NOT install the UPS in areas that are subject to high humidity.

5.DO NOT install the UPS in areas that allow exposure to direct sunlight.

6.DO NOT install the UPS in areas that allow exposure to high levels of airborne dust, metal particles, or flammable gases.

7.DO NOT install the UPS in areas near sources of electrical noise. Ensuring a proper earth ground will reduce the effects of electrical noise and will reduce the potential for electrical shock.

8.DO NOT install the UPS in areas that would allow fluids or any foreign object to get inside the

UPS.

9.The UPS generates and can radiate radio-frequency energy during operation. Although RFI noise filters are installed inside of the unit, there is no guarantee that the UPS will not influence some sensitive devices that are operating near by. If such interference is experienced, the UPS should be installed farther away from the affected equipment and/or powered from a different source than that of the affected equipment.

10.The user should provide output over-current protection for hardwired UPS systems. See the section titled Specifications on page 15 and 18 for the device rating.

11.After ensuring that all power sources are turned off and isolated in accordance with established lockout/tagout procedures, connect the power source wiring of the correct voltage to the input terminals of the UPS.

12.Connect the output terminals of the UPS to the load (refer to NEC Article 300 – Wiring Methods and Article 310 – Conductors For General Wiring). Size the branch circuit conductors in accordance with NEC Table 310.16.

Conductor Routing and Grounding

1.Use separate metal conduits for routing the input power, output power, and control circuits.

2.Follow the wire size and tightening torque specifications listed on page 11.

3.Always ground the unit to reduce the potential for electrical shock and to help reduce electrical noise.

4.A separate ground cable should be run inside the conduit with the input power, output power, and control circuits.

Warning

THE METAL OF CONDUIT IS NOT AN ACCEPTABLE GROUND.

1600EP Series Instruction Manual

Page 15
Image 15
Toshiba 1600EP Series manual Installation Precautions, Conductor Routing and Grounding

1600EP Series specifications

The Toshiba 1600EP Series is a notable entry in the landscape of multifunctional printers that has garnered attention for its robust performance and technological innovations. Targeted at small to medium-sized businesses, this series combines cost efficiency with high-quality output, making it an ideal choice for various office environments.

One of the standout features of the 1600EP Series is its impressive print speed. Capable of delivering up to 28 pages per minute, the printer significantly enhances productivity and meets the fast-paced demands of a modern office. Users can rely on quick first-page-out times, which is essential for handling numerous print jobs throughout the day.

In addition to speed, the Toshiba 1600EP Series emphasizes superior print quality. With a resolution of up to 1200 x 1200 dpi, it ensures that documents are sharp, clear, and professional-looking. Whether it’s text, graphics, or images, the printer excels in producing high-definition prints that can leave a lasting impression.

The 1600EP Series also integrates advanced digital technology, featuring a user-friendly touchscreen display that simplifies operation. This intuitive interface allows users to navigate through printing, copying, and scanning functions with ease. The series supports various paper sizes and types, enabling customization for different office needs.

Moreover, the Toshiba 1600EP Series is known for its sustainability features. It incorporates energy-saving modes and is designed for low power consumption, aligning with the growing emphasis on environmentally responsible practices in business operations. This eco-friendly approach is complemented by the use of long-lasting consumables, reducing the frequency of replacements and overall waste.

Networking capabilities are another highlight of the 1600EP Series. With built-in Wi-Fi and the option for mobile printing, users can connect seamlessly to various devices, enhancing accessibility and convenience. This flexibility ensures that employees can print from their smartphones, tablets, or laptops, streamlining workflow.

In summary, the Toshiba 1600EP Series stands out in the multifunction printer market, offering a blend of speed, quality, and innovative technology. Its user-centric design, coupled with sustainable features and strong connectivity options, makes it a reliable choice for businesses aiming to enhance their printing capabilities while maintaining efficiency and environmental responsibility. As organizations continue to seek reliable office solutions, the Toshiba 1600EP Series remains a compelling option worth considering.