Toshiba 1600EP Series manual Standard Models 10kVA 14kVA 18kVA 22kVA, Capacity, kVA 8.5 kW1

Models: 1600EP Series

1 64
Download 64 pages 52.93 Kb
Page 26
Image 26
Standard Models: 10kVA; 14kVA; 18kVA; 22kVA

Standard Models: 10kVA; 14kVA; 18kVA; 22kVA

Capacity

10 kVA (8.5 kW)1

 

14 kVA (11.9 kW)1

 

18 kVA (15.3 kW)1

 

22 kVA (18.7 kW)1

General

 

 

 

 

 

 

 

Topology

 

 

True On-line

 

Certifications

 

 

UL, CUL, ISO 9001, NEMA/PE1-1993

 

Input Characteristics

 

 

 

 

 

 

 

Input Voltage

 

Single-phase, 208/240 VAC, +10% to –30% 1 1

 

 

 

 

 

Input Frequency

 

 

45-65 Hz (auto-sensing)

 

Input Capacity

10 kVA

 

14 kVA

 

18 kVA

Input Power Factor

 

 

> 0.95 for all loads

 

Current THD (linear load)

 

< 5%

 

 

Included AC Input Breaker

63 A / 277 V

 

100 A / 277 V

 

125 A / 277 V

rating

 

 

 

 

 

 

 

Battery Characteristics

 

 

 

 

 

 

 

Battery Type

 

Valve Regulated Lead Acid, Flame Retardant

 

Backup time, fully charged

10 kVA

 

14 kVA

 

18 kVA

 

22 kVA

@ 0.7 power factor, 77 F

 

 

7 min minimum2

 

 

 

5 min

Backup time, fully charged

5 min

 

7 min

 

5 min

 

3 min

@ 0.85 power factor, 77 F

minimum2

 

minimum2

 

minimum2

 

minimum2

Recharge Time

24hr. (full), 12hr.(90%) for internal batteries only3

Battery Voltage (Nominal)

 

 

288 VDC

 

Output Characteristics

 

 

 

 

 

 

 

Output Voltage

 

 

Single-phase, 240/208/120 volts

 

Output Voltage Regulation

 

±3%

 

 

Output Frequency

±0.5Hz/1Hz/1.5Hz (factory or authorized service center selectable only)

AUTO/MAN Frequency

Factory or authorized service center selectable only

Voltage THD

 

< 3% for linear load; < 6% for non-linear load

 

Common-Mode Noise

 

 

< .5 Vrms

 

Rated Load Power Factor

 

 

0.85 (0.6 - 1.0) lagging

 

Efficiency (AC-DC-AC)

 

 

> 83% (without battery charge)

 

Voltage Transient

 

 

< ±8% (Load of 0 to 100 %)

 

Rated Output Current (rms)

41.6 A

 

58.0 A

 

75.0 A

 

91.6 A

Max. Peak Output Current

125 A

 

174 A

 

225 A

 

275 A

Inverter Overload Capacity

 

 

125%-30 sec/150%-10 sec

 

Bypass Overload Capacity

 

 

125%-10 min./1000%-1 cycle

 

Crest Factor

 

 

 

3.0

 

 

1.Input/output figures rated for 240 volts. Output ratings given for 0.85PF are only valid when the input voltage is greater than 204 volts; otherwise, ratings given for 0.70PF are applicable.

2.Battery backup time may vary depending on the operating conditions and ambient temperature at the installation site.

3.An initial charge time of 24 hrs. is necessary to obtain proper battery performance level before unit is placed in operation.

18

1600EP Series Instruction Manual

Page 26
Image 26
Toshiba 1600EP Series manual Standard Models 10kVA 14kVA 18kVA 22kVA, Capacity, kVA 8.5 kW1, kVA 15.3 kW1, kVA 18.7 kW1