3.4 Personalisation (optional)

Function

Personalisation parameters can be set and modified using the "UPS Driver" software installed on a computer that is connected to the UPS (see section 2.3 Connection to the RS 232 (or USB) communications port).

Check that the RS 232 25 or USB 26 cable is properly connected.

"UPS Driver" installation:

1 - Insert the "UPS Driver" diskette in the drive of a PC running Windows. 2 - Select the disk drive (A:\).

3 - Double-click "upsdriv.exe".

Once "UPS Driver" has been installed, UPS parameters can be modified in a window containing a number of tabs, each presenting a set of parameters.

"ON / OFF conditions" tab

Personalisable function

Default setting

Options

 

 

 

Automatic start

Enabled

Disabled

 

 

 

Cold start (battery power)

Enabled

Disabled

 

 

 

Forced shutdown

Enabled

Disabled

 

 

 

Sleep mode

Disabled

Enabled

 

 

 

UPS ON / OFF via software

Enabled

Disabled

 

 

 

"Battery" tab

Personalisable function

Default setting

Options

 

 

 

 

 

Once a week

Automatic "Battery test" intervals

Every day

Once a month

 

 

No test

 

 

 

"Low-battery warning" threshold

20% remaining battery backup time

40% remaining battery backup time

 

 

 

51031604EN/AB - Page 19

Image 19
Contents Pulsar EXtreme Introduction Product safety SafetySafety rules Safety of personsForeword Using this documentPictograms Contents Maintenance Pulsar EXtreme range PresentationTower model Rack model Tower model BackUSB Control panel Alarms Battery Load RemainingUnpacking and checks Installation12 51031604EN/AB Installation of the rack version Connection to the RS 232 or USB communications port optional Installation of the communications-card option Connections All connected equipment is energised OperationStart-up Bargraph indicationsEquipment connected to the UPS is supplied by the battery Transfer to battery powerThreshold for the low-battery warning End of backup timeFunction Battery tabPersonalisable function Default setting Options Personalisation optionalBypass tab Connected equipment is no longer supplied with powerShutdown Output tabSignification MaintenanceTroubleshooting IndicationIndication Signification Correction Safety rules Replacement of the battery module24 51031604EN/AB Environment UPS recycling at the end of service lifeSimplified diagram Operating conditions Technical characteristicsAppendices UPS on / OFF via software GlossaryConnection Index

1000C, 700C specifications

MGE UPS Systems offers a robust range of Uninterruptible Power Supply (UPS) solutions, with two noteworthy models being the 700C and 1000C. These models are designed to provide reliable power protection for various applications, ensuring that critical equipment remains operational during power disturbances.

The MGE UPS Systems 700C features a power capacity of 700 VA, ideal for small servers and workstations. Its compact design allows it to fit seamlessly in both office and home environments. One of the main features of the 700C is its line-interactive technology, which offers enhanced power management capabilities without the need for a bulky setup. This model includes an LCD display that provides real-time information on battery status, load capacity, and utility power conditions, contributing to better monitoring and management of connected devices.

On the other hand, the MGE UPS Systems 1000C boasts a higher power capacity of 1000 VA, accommodating the needs of larger systems. This model also employs line-interactive technology and comes with an integrated automatic voltage regulation (AVR) feature. The AVR helps stabilize output voltage and ensures that connected equipment receives consistent power even when input voltage fluctuates. Additionally, the 1000C is equipped with multiple output sockets, allowing users to connect various devices simultaneously without compromising performance.

Both the 700C and 1000C utilize advanced battery technologies to enhance their overall reliability and life span. They support both sealed lead-acid and lithium-ion batteries, providing users with flexibility based on their specific requirements. Moreover, the hot-swappable battery feature ensures that batteries can be replaced without turning off the UPS, minimizing downtime for connected equipment.

A key characteristic of both models is their energy efficiency. With features designed to minimize power loss during operation, these UPS systems are not only cost-effective but also environmentally friendly. The MGE UPS Systems 700C and 1000C models provide users with peace of mind, knowing that their critical systems are safeguarded against power interruptions, voltage sags, and surges, ensuring continuous operation and data integrity. With their blend of innovative technology, efficiency, and ease of use, these UPS systems are perfect choices for both small and medium-sized businesses looking to protect their electronic assets.