MGE UPS Systems 700C, 1000C user manual Index, Connection

Page 28

6. Appendices

 

6.3 Index

 

A

 

AC power

 

Failure

18

Frequency tolerance

20

Return

18

Automatic start

19

B

 

Bargraph

10-17

Battery

 

Battery test

19

End of backup time

18

Fault

10-17

Handling precautions

3

Low-battery warning

19

Recycling

3-25

Replacement

23-24

Transfer to battery power

18

Buttons

8-9-10

Buzzer

17-18

Bypass

 

Automatic bypass

10-20-22

C

 

Communication

8-9-14-15

Connection

 

Additional battery module

8-9

Communications card

14

RS 232 communications port

14

USB communications port

14

D

 

Dimensions

7

E

 

Environnement

2-3-24

F

 

Fault (UPS)

10-17-21-22

L

 

LEDs

8-9-10

Lamp test

10

M

 

Mode

 

ON LINE mode

10

O

 

Overload

10-20-21

S

 

Safety

3

Shutdown

 

Buzzer

10-18

Forced shutdown

19

UPS ON / OFF via software

19

UPS shutdown

10-20

Sleep mode

19

Automatic restart

19-20

Software

 

UPS Driver

19

Start-up

17

T

 

Technical characteristics

26

Temperature

 

Excessive ambient temp

26

Transfer (forced)

10

U

 

UPS Driver

19

UPS fault

10-17-20

UPS storage

3

W

 

Web site

2

Weight

7

Page 28 - 51031604EN/AB

Image 28
Contents Pulsar EXtreme Introduction Safety Safety rulesSafety of persons Product safetyForeword Using this documentPictograms Contents Maintenance Pulsar EXtreme range PresentationTower model Rack model Back Tower modelUSB Alarms Battery Load Remaining Control panelInstallation Unpacking and checks12 51031604EN/AB Installation of the rack version Connection to the RS 232 or USB communications port optional Installation of the communications-card option Connections Operation Start-upBargraph indications All connected equipment is energisedTransfer to battery power Threshold for the low-battery warningEnd of backup time Equipment connected to the UPS is supplied by the batteryBattery tab Personalisable function Default setting OptionsPersonalisation optional FunctionConnected equipment is no longer supplied with power ShutdownOutput tab Bypass tabMaintenance TroubleshootingIndication SignificationIndication Signification Correction Replacement of the battery module Safety rules24 51031604EN/AB UPS recycling at the end of service life EnvironmentSimplified diagram Operating conditions Technical characteristicsAppendices Glossary UPS on / OFF via softwareIndex Connection

1000C, 700C specifications

MGE UPS Systems offers a robust range of Uninterruptible Power Supply (UPS) solutions, with two noteworthy models being the 700C and 1000C. These models are designed to provide reliable power protection for various applications, ensuring that critical equipment remains operational during power disturbances.

The MGE UPS Systems 700C features a power capacity of 700 VA, ideal for small servers and workstations. Its compact design allows it to fit seamlessly in both office and home environments. One of the main features of the 700C is its line-interactive technology, which offers enhanced power management capabilities without the need for a bulky setup. This model includes an LCD display that provides real-time information on battery status, load capacity, and utility power conditions, contributing to better monitoring and management of connected devices.

On the other hand, the MGE UPS Systems 1000C boasts a higher power capacity of 1000 VA, accommodating the needs of larger systems. This model also employs line-interactive technology and comes with an integrated automatic voltage regulation (AVR) feature. The AVR helps stabilize output voltage and ensures that connected equipment receives consistent power even when input voltage fluctuates. Additionally, the 1000C is equipped with multiple output sockets, allowing users to connect various devices simultaneously without compromising performance.

Both the 700C and 1000C utilize advanced battery technologies to enhance their overall reliability and life span. They support both sealed lead-acid and lithium-ion batteries, providing users with flexibility based on their specific requirements. Moreover, the hot-swappable battery feature ensures that batteries can be replaced without turning off the UPS, minimizing downtime for connected equipment.

A key characteristic of both models is their energy efficiency. With features designed to minimize power loss during operation, these UPS systems are not only cost-effective but also environmentally friendly. The MGE UPS Systems 700C and 1000C models provide users with peace of mind, knowing that their critical systems are safeguarded against power interruptions, voltage sags, and surges, ensuring continuous operation and data integrity. With their blend of innovative technology, efficiency, and ease of use, these UPS systems are perfect choices for both small and medium-sized businesses looking to protect their electronic assets.