MGE UPS Systems 3200C, 2200C user manual Index, Connection

Page 27

6.3 Index

A

 

Remote power off

19

Automatic bypass

9-18-20

Automatic start

17

B

 

Bargraph

9-15

Battery

 

End of backup time

16

Fault

9-15

Low-battery warning

17

Recycling

24

Replacement

22-23

Transfer to battery power

16

Buttons

8-9

Buzzer

15-16

Buzzer shutdown

9

C

 

Connection

 

Additional battery module

8

Communications card

13

RS232 communications port

13

USB communications port

13

Communication

8-13

D

 

Dimensions

7

E

 

Environment

2-24

Excessive ambient temperature

25

F

 

Forced shutdown

17

6. Appendices

L

 

Lamp test

9

LEDs

8-9

O

 

ON LINE mode

9

Overload

9-18-20

P

 

Personnalisation

17

Battery

17

By-pass

18

On/Off conditions

17

Output

18

Programmable outlets

8-9-15

S

 

Sleep mode

17

Automatic restart

17-18

Start-up

15

T

 

Technical characteristics

25

Transfer (forced)

9

U

 

UPS Driver

17

UPS fault

9-15-20-21

UPS ON / OFF via software

17

UPS shutdown

18

W

 

Web site

2

Weight

7

34007532EN/AA - Page 27

Image 27
Contents Pulsar EXtreme Introduction Using this document ForewordPictograms 4 34007532EN/AA Contents Technical characteristics Glossary Index Tower position PresentationStandard positions Rack positionPulsar EXB 2200 BackPulsar EXtreme 2200C Pulsar EXtreme 3200CAlarms Battery Control panelLoad Unpacking and parts check InstallationInstallation in rack position Connect the two supports for the upright position Installation in tower positionConnection to the RS232 or USB communications port optional Installation of the communications-card optionConnections Status LEDs 20 and 21 for programmable outlets 1 OperationStart-up Bargraph indicationsEquipment connected to the UPS is supplied by the battery Transfer to battery powerThreshold for the low-battery warning End of backup timeOn / OFF conditions tab Battery tabPersonalisation optional FunctionPress button 16 return to the OFF position UPS shutdownOutput tab Bypass tabInstallation and test of the remote power off function UPS remote power offMaintenance TroubleshootingIndication Diagnostic Correction Indication Signification Correction Replacement of the battery module Safety rulesRemoval of battery module Reinstallation of the battery module Packing UPS recycling at the end of service lifeEnvironment This product has been designed to respect the environmentAppendices Technical characteristicsUPS on / OFF via software GlossaryConnection Index28 34007532EN/AA

3200C, 2200C specifications

MGE UPS Systems is a renowned manufacturer specializing in uninterruptible power supplies (UPS), and their models 2200C and 3200C are exemplary representations of their commitment to quality, efficiency, and technological advancement. Both models are designed to ensure that critical equipment remains powered during outages, safeguarding important data and maintaining operational continuity.

The MGE UPS 2200C is a versatile and compact UPS solution that provides a robust capacity of 2200 VA. Its design caters to small to medium-sized businesses that require reliable power protection for servers, network equipment, and telecommunications systems. This model features a double conversion architecture that delivers clean, stable power, effectively insulating connected devices from power irregularities such as surges and sags. One of the key technologies employed in the 2200C is the use of IGBT (Insulated Gate Bipolar Transistor) technology, which enhances efficiency and reduces overall energy consumption.

On the other hand, the MGE UPS 3200C offers a higher capacity of 3200 VA, making it suitable for larger setups that demand more power protection. Like its smaller counterpart, the 3200C utilizes double conversion technology, ensuring optimal power quality at all times. This model incorporates advanced features such as adjustable output voltage and frequency to match the requirements of specific equipment. Additionally, it supports parallel operation, allowing for scalability and redundancy, which are crucial for mission-critical applications.

Both UPS models come integrated with an LCD interface, providing real-time monitoring of critical parameters such as input/output voltage, load levels, and battery status. This user-friendly display allows for easy management and maintenance, which is essential for IT administrators.

Battery management in both models is enhanced through intelligent charging algorithms that prolong battery life and reliability. They also feature multiple communication options, including USB and RS-232, facilitating seamless integration with various management software for remote monitoring and control.

In conclusion, the MGE UPS 2200C and 3200C are efficient and reliable UPS solutions equipped with advanced technologies and features that cater to a wide range of power protection needs. Their robust design, high efficiency, and user-friendly interfaces make them ideal choices for businesses looking to safeguard their critical operations against power disturbances.