American Power Conversion XR, Smart-UPS VT operation manual General safety

Page 10

Safety – IMPORTANT SAFETY INSTRUCTIONS

General safety

Two people to lift components weighing between 40 - 70 lbs / 18 - 32 kg.

Indicates that a switch or current protection device is in the ON position.

Indicates that a switch or a breaker is in the OFF position.

WARNING!

Hazardous electrically-charged parts inside the UPS are energized from the battery supply even when the AC power is disconnected. Follow Total-Power-Off Procedure to completely de-energize the system.

For configurations including customer-supplied external batteries, refer to manufacturer’s battery installation and maintenance instructions.

Note

2

Smart-UPS® VT 10-30 kVA, 208/220 V and XR Battery Enclosure Operation Manual 990-1599B

Image 10
Contents Smart-UPSVT and XR Battery Enclosure Page Smart-UPSVT and XR Battery Enclosure10-30 kVA 208/220 Page Contents Display Messages/Troubleshooting Warranty Page Symbols used in this guide Environmental symbolsGeneral safety Operation Introduction13.85 in/352 mm Enclosures Smart-UPS VT Family Range20.59 in/523 mm Enclosures Serial number Type labelNormal operation Battery operationOperation Modes Bypass operation or static bypass operation utilityWrap-around maintenance bypass Display IntroductionNavigation Menu-driven user functionsBasic display navigation principles Control functionsSelect YES, Turn Load On Status viewsClock set-up DateLogging ExampleAlarm threshold Display setupVol Diagnostics screen Display Messages/Troubleshooting Display messagesOperation Display Messages/Troubleshooting Display message Meaning Corrective action Front Panel Removal/Installation Front Panel removalInstallation Total-Power-Off Procedure Restart Procedure Power applicationVoltage confirmation EnterMechanical Bypass Lever Mechanical BypassTurn into mechanical bypass 990-1599B Network Management Card replacement Network Management Card with Environmental MonitorGeneral safety prior to module replacement Battery ReplacementBattery Module Removal and installation of Battery Locks if applicable Battery Module removal How to install a Battery ModuleUPS / XR How to Obtain Replacement Parts Orderable partsMaintenance Bypass Panel Operation procedureTerms of warranty APC product coveredDrawings, descriptions Warranty claims procedureAssignment of warranties ExclusionsWarranty Limited Factory Warranty Appendix UPS Components and OptionsV T 1 0 K F 1 B 2 S Part number coding52.8 lb / 4 x User interface  Appendix UPS Components and Options Foot print Humidity Sensor Battery Securing Bracket and Floor Anchoring OptionsExtended Run Battery Enclosure XR Battery Enclosure Battery Module weightPart numbers for XR Battery Enclosures Part number for Battery ModuleMaintenance Bypass Panels with Power Distribution Capability 990-1599B