Serial number

The serial number is available on the type label on the rear side of the UPS.

Type label

 

Hotline in US/Canada/LAM: +1 800 800 4APC

 

 

 

 

 

 

Hotline in EMEA:

+353 91 70 2000

 

 

 

 

 

 

Worldwide Support numbers: www.apcc.com/support/service/geomap_world.dfm

 

 

 

 

 

 

 

 

 

 

 

Unit Serial No

APC SKU

Model

Battery Capacity

Apparent/

Rated Input Current

Rated Output Current

Battery Current

 

 

 

@– 192V DC

Active Power

 

 

 

 

 

 

 

 

 

 

 

 

SUVT10KF1B2S

APC Smart-UPS VT 10kVA 208V

7.2Ah

 

 

 

 

 

w/1 Batt. Module Exp. to 2

 

 

 

 

SUVTF10KB2F

 

 

 

 

 

 

 

 

 

 

 

 

 

SUVT10KF2B2S

APC Smart-UPS VT 10kVA 208V

14.4Ah

 

 

 

 

 

 

 

 

 

 

w/2 Batt. Modules

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUVT10KF1B4S

APC Smart-UPS VT 10kVA 208V

7.2Ah

 

 

 

 

 

w/1 Batt. Module Exp. to 4

10kVA/8kW

27.1A

27.8A

 

 

 

 

28.9A

 

 

 

 

 

208V

208V

 

SUVT10KF2B4S

APC Smart-UPS VT 10kVA 208V

14.4Ah

 

 

 

 

 

w/2 Batt. Modules Exp. to 4

 

 

 

 

SUVTF10KB4F

 

 

 

 

 

 

 

 

 

 

 

 

 

SUVT10KF3B4S

APC Smart-UPS VT 10kVA 208V

21.6Ah

 

 

 

 

 

 

 

 

 

 

w/3 Batt. Modules Exp. to 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUVT10KF4B4S

APC Smart-UPS VT 10kVA 208V

28.8Ah

 

 

 

 

 

w/4 Batt. Modules

 

 

 

 

 

 

 

 

 

 

 

SUVTF15KB2F

SUVT15KF2B2S

APC Smart-UPS VT 15kVA 208V

14.4Ah

 

 

 

 

w/2 Batt. Modules

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUVT15KF2B4S

APC Smart-UPS VT 15kVA 208V

14.4Ah

 

40.6A

41.6A

 

 

 

w/2 Batt. Modules Exp. to 4

 

15kVA/12kW

43.3A

 

 

 

208V

208V

SUVTF15KB4F

SUVT15KF3B4S

APC Smart-UPS VT 15kVA 208V

21.6Ah

 

 

 

 

 

 

 

 

w/3 Batt. Modules Exp. to 4

 

 

 

 

 

 

SUVT15KF4B4S

APC Smart-UPS VT 15kVA 208V

28.8Ah

 

 

 

 

 

 

w/4 Batt. Modules

 

 

 

 

 

 

SUVT20KF2B4S

APC Smart-UPS VT 20kVA 208V

14.4Ah

 

 

 

 

 

w/2 Batt. Modules Exp. to 4

 

 

 

 

 

 

 

 

 

 

55.5A

 

 

 

 

 

 

 

 

 

 

APC Smart-UPS VT 20kVA 208V

21.6Ah

 

54.2A

 

SUVTF20KB4F

SUVT20KF3B4S

20kVA/16kW

208V

57.7A

w/3 Batt. Modules Exp. to 4

 

208V

 

 

 

 

 

 

 

SUVT20KF4B4S

APC Smart-UPS VT 20kVA 208V

28.8Ah

 

 

 

 

 

w/4 Batt. Modules

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUVT30KF3B4S

APC Smart-UPS VT 30kVA 208V

21.6Ah

 

81.3A

83.3A

 

 

w/3 Batt. Modules Exp. to 4

 

 

SUVTF30KB4F

 

 

30kVA/24kW

86.6A

 

 

208V

208V

 

SUVT30KF4B4S

APC Smart-UPS VT 30kVA 208V

28.8Ah

 

 

 

 

 

 

 

 

w/4 Batt. Modules

 

 

 

 

 

 

 

 

 

 

 

Voltage & Connection Types

 

 

Batteries

 

 

 

 

 

 

 

AC Input

AC Output

DC Input

Date

Date for 1.

Date for 2.

installed

Replacement

Replacement

 

 

 

208Y/120V 4W+GND 60Hz

208Y/120V 4W+GND 60Hz

+/- 192V

 

 

 

 

 

 

 

 

 

SEE INSTALLATION INSTRUCTIONS

BEFORE CONNECTING TO THE

SUPPLY

THIS REAR COVER MUST BE

PLACED ON UPS

885-2321C_rev04

990-1599B Smart-UPS® VT 10-30 kVA, 208/220 V and XR Battery Enclosure Operation Manual

5

Image 13
Contents Smart-UPSVT and XR Battery Enclosure Page Smart-UPSVT and XR Battery Enclosure10-30 kVA 208/220 Page Contents Display Messages/Troubleshooting Warranty Page Environmental symbols Symbols used in this guide General safety Introduction Operation13.85 in/352 mm Enclosures Smart-UPS VT Family Range20.59 in/523 mm Enclosures Type label Serial numberOperation Modes Battery operationNormal operation Bypass operation or static bypass operation utilityWrap-around maintenance bypass Introduction DisplayMenu-driven user functions NavigationControl functions Basic display navigation principlesStatus views Select YES, Turn Load OnDate Clock set-upExample LoggingDisplay setup Alarm thresholdVol Diagnostics screen Display messages Display Messages/TroubleshootingOperation Display Messages/Troubleshooting Display message Meaning Corrective action Front Panel removal Front Panel Removal/InstallationInstallation Total-Power-Off Procedure Power application Restart ProcedureEnter Voltage confirmationMechanical Bypass Lever Mechanical BypassTurn into mechanical bypass 990-1599B Network Management Card with Environmental Monitor Network Management Card replacementGeneral safety prior to module replacement Battery ReplacementBattery Module Removal and installation of Battery Locks if applicable How to install a Battery Module Battery Module removalUPS / XR Orderable parts How to Obtain Replacement PartsOperation procedure Maintenance Bypass PanelAPC product covered Terms of warrantyAssignment of warranties Warranty claims procedureDrawings, descriptions ExclusionsWarranty Limited Factory Warranty UPS Components and Options AppendixPart number coding V T 1 0 K F 1 B 2 S52.8 lb / 4 x   User interfaceAppendix UPS Components and Options Foot print Humidity Sensor Options Battery Securing Bracket and Floor AnchoringBattery Module weight Extended Run Battery Enclosure XR Battery EnclosurePart number for Battery Module Part numbers for XR Battery EnclosuresMaintenance Bypass Panels with Power Distribution Capability 990-1599B