American Power Conversion XR, Smart-UPS VT operation manual Total-Power-Off Procedure

Page 30

Total-Power-Off Procedure

WARNING!

Risk of electric shock – parts inside the UPS and XR Batterty Enclosure are energized from the battery supply even when the AC power is disconnected. Before electrical installation begins, follow the Total-Power-Off procedure to completely de-energize the system.

ON

OFF

Utility/

Mains

breaker

Serial:

Model:

BATTERY UNIT

UPS

XR Battery Enclosure

Set the DC disconnect switch on the XR Enclosure (if available) to the OFF position.

Remove all batteries from the system, or, alternatively, pull out all batteries to the red disconnect line shown on the battery. To ensure sufficient stability, do not pull batteries out beyond the red disconnect line unless completely removing them from the Enclosure.

Set the utility breaker to the OFF or LOCKED-OUT position. If the UPS has dual mains supply, set both supplies to the OFF or LOCKED-OUT position.

WARNING!

Correct lock-out procedures at utility breaker must be followed. If necessary, install a padlock.

22

Smart-UPS® VT 10-30 kVA, 208/220 V and XR Battery Enclosure Operation Manual 990-1599B

Image 30
Contents Smart-UPSVT and XR Battery Enclosure Page Smart-UPSVT and XR Battery Enclosure10-30 kVA 208/220 Page Contents Display Messages/Troubleshooting Warranty Page Symbols used in this guide Environmental symbolsGeneral safety Operation IntroductionSmart-UPS VT Family Range 13.85 in/352 mm Enclosures20.59 in/523 mm Enclosures Serial number Type labelNormal operation Battery operationOperation Modes Bypass operation or static bypass operation utilityWrap-around maintenance bypass Display IntroductionNavigation Menu-driven user functionsBasic display navigation principles Control functionsSelect YES, Turn Load On Status viewsClock set-up DateLogging ExampleAlarm threshold Display setupVol Diagnostics screen Display Messages/Troubleshooting Display messagesOperation Display Messages/Troubleshooting Display message Meaning Corrective action Front Panel Removal/Installation Front Panel removalInstallation Total-Power-Off Procedure Restart Procedure Power applicationVoltage confirmation EnterMechanical Bypass Mechanical Bypass LeverTurn into mechanical bypass 990-1599B Network Management Card replacement Network Management Card with Environmental MonitorBattery Replacement General safety prior to module replacementBattery Module Removal and installation of Battery Locks if applicable Battery Module removal How to install a Battery ModuleUPS / XR How to Obtain Replacement Parts Orderable partsMaintenance Bypass Panel Operation procedureTerms of warranty APC product coveredDrawings, descriptions Warranty claims procedureAssignment of warranties ExclusionsWarranty Limited Factory Warranty Appendix UPS Components and OptionsV T 1 0 K F 1 B 2 S Part number coding52.8 lb / 4 x User interface  Appendix UPS Components and Options Foot print Humidity Sensor Battery Securing Bracket and Floor Anchoring OptionsExtended Run Battery Enclosure XR Battery Enclosure Battery Module weightPart numbers for XR Battery Enclosures Part number for Battery ModuleMaintenance Bypass Panels with Power Distribution Capability 990-1599B

XR, Smart-UPS VT specifications

The American Power Conversion (APC) Smart-UPS VT,XR is a premier uninterruptible power supply (UPS) design tailored for critical power applications. This advanced UPS system is specifically engineered for medium to large data centers and IT equipment that require high availability and robust protection against power disturbances. With its scalable architecture and cutting-edge technologies, the Smart-UPS VT,XR guarantees both performance and efficiency.

One of the standout features of the Smart-UPS VT,XR is its modular design. This allows users to expand the system's capacity as their power requirements grow, making it a flexible solution for evolving business needs. The modularity reduces upfront investment and aids in easy upgrades without significant downtime. The system supports hot-swappable batteries, which ensure that continuous power is maintained even during battery replacement.

The Smart-UPS VT,XR is equipped with multi-level battery management technology. This advanced feature optimally charges and discharges batteries to enhance their overall lifespan and performance. The UPS employs a unique Eco Mode, which improves energy efficiency by providing high-efficiency operation while maintaining reliable backup power. This not only reduces operational costs but also lowers the system's carbon footprint.

In terms of connectivity, the Smart-UPS VT,XR features an intuitive LCD touch screen interface for real-time monitoring and administration. Users can easily access important metrics such as runtime, load, and battery health, thereby improving maintenance management. Furthermore, it incorporates advanced communication options that facilitate integration with network management systems, ensuring seamless operation and monitoring across remote locations.

The power factor capability of the Smart-UPS VT,XR is also noteworthy, supporting a power factor of up to 1.0. This characteristic allows for maximum utilization of the UPS capacity, which is essential for powering modern high-density equipment. Additionally, the UPS supports a wide input voltage range and frequency tolerance, accommodating diverse power environments and ensuring reliability in various installations.

Overall, the APC Smart-UPS VT,XR stands out as a top-tier UPS solution for businesses seeking unyielding performance and efficiency. Its combination of modularity, advanced battery management, energy-saving features, and robust connectivity options makes it an invaluable asset for any mission-critical environment. Whether in a data center, telecommunications hub, or hospital, the Smart-UPS VT,XR promises reliability and peace of mind in power management.