American Power Conversion AP9222EXP manual Life-Support Policy

Page 38

Product Information

Life-Support Policy

General policy As a general policy, American Power Conversion (APC) does not recommend the use of any of its products in life-support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life-support device or to significantly affect its safety or effectiveness. APC does not recommend the use of any of its products in direct patient care. APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that (a) the risks of injury or damage have been minimized, (b) the customer assumes all such risks, and (c) the liability of American Power Conversion is adequately protected under the circumstances.

Examples of life- The term life-support device includes but is not limited to neonatal

support devices oxygen analyzers, nerve stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfusion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators (for adults or infants), anesthesia ventilators, infusion pumps, and any other devices designated as “critical” by the U.S. FDA.

Hospital-grade wiring devices and leakage current protection may be ordered as options on many APC UPS systems. APC does not claim that units with this modifications are certified or listed as hospital-grade by APC or any other organization. Therefore these units do not meet the requirements for use in direct patient care.

MasterSwitch VM User’s Guide

33

Image 38
Contents MasterSwitch VM Thank You MasterSwitch VM ContentsContents Specifications Warranty InformationTroubleshooting Life-Support PolicyProduct Description Feature DescriptionIntroduction MasterSwitch VM Controller IntroductionLEDs Status DescriptionOperating MasterSwitch VM Configuring outlets for operation Is turned on When these two delays expire, the outlet will be turned on Outlet will be turned on Threshold has been exceeded Outlets do not turn on when the Overload WarningOutlets always turn on Overload Warning and the load exceeds the Overload WarningManaging MasterSwitch VM Management InterfacesInterface Managing MasterSwitch VMControl Console Telnet, for remote managementManaging MasterSwitch VM Account, and up to 16 Outlet User accounts Password-Protected AccountsAccount access to Outlets and menuMenu Items OutletsMenu Items OutletsMasterSwitch VM Unit ConfigurationOutlet Configuration Links Dir. You will see a listing similar to the following ftpdir Event LogInterface or by pressing C TRL + L in the Control Console Similar to the following MasterSwitch VM unit always uses four-digit yearRepresentation when logging and displaying event data However, you may need to select a four-digit date formatNetwork TCP/IPDefinition Snmp Access ControlTelnet/Web Snmp Trap Receiver Trap Receiver IP toItems SystemUser Manager For Outlet User Manager Outlet UserManager File Transfer IdentificationDate/Time Enable Bootp ToolsHelp Security Features SecurityAuthentication Security Interface Security Access MethodsWarranty Information Product InformationTroubleshooting Product InformationLife-Support Policy MasterSwitch VM power distribution unit AP9222 SpecificationsFollowing table shows the product specifications for ProductMasterSwitch VM Controller AP9221NX166 AP9221NX166Help Features IndexIndex APC Worldwide Customer Support Regional centers