Chapter 3 Troubleshooting and Maintenance
Troubleshooting Power Supply Failure
Problem | Possible Cause |
| Solution |
Power Supply | No input voltage detected at connector J1, pins | Replace the wiring harness | |
Failure | 1 and 2. |
|
|
| Input voltage present at connector J1, pins 1 | Disconnect power from the | |
| and 2. |
| supply |
| No input voltage at the black and white wires | Replace the Euro block | |
| input lines. |
|
|
| Input voltage present at the black and white | Replace the wiring harness. | |
| wires input lines. |
|
|
Reconnect power to the CTFLM. |
|
| |
Power Supply | No voltage at the Coax stinger. |
| Replace the CTFLM module |
Failure |
|
|
|
Maintenance |
|
|
|
Routine Maintenance Schedule |
|
| |
Operation |
| Interval |
|
Visual Inspection |
|
|
|
External Surfaces | Semiannually |
| |
Connectors | Annually |
| |
Operator Controls | Annually |
| |
Wiring/Cable Assemblies | Annually |
| |
Cleaning |
|
|
|
External Surfaces | Annually |
| |
External Controls/Receptacles | Annually |
| |
Internal Receptacles/Circuit Boards | Annually |
| |
Performance Verification |
|
| |
Refer to Initial Startup in the manual | Semiannually |
|
6