Chapter 3 Troubleshooting and Maintenance
Troubleshooting Power Supply Failure
Problem | Possible Cause | Solution |
Power Supply | No input voltage detected at connector J1, pins | Replace the wiring harness |
Failure | 1 and 2. |
|
|
|
|
| Input voltage present at connector J1, pins 1 | Disconnect power from the |
| and 2. | supply |
|
|
|
| No input voltage at the black and white wires | Replace the Euro block |
| input lines. |
|
|
|
|
| Input voltage present at the black and white | Replace the wiring harness. |
| wire input lines. |
|
|
|
|
| No voltage at the Coax stinger. | Replace the CTFLM module |
|
|
|
Maintenance
Routine Maintenance Schedule
Operation | Interval |
Visual Inspection |
|
External Surfaces | Semiannually |
Connectors | Annually |
Operator Controls | Annually |
Wiring/Cable Assemblies | Annually |
|
|
Cleaning |
|
External Surfaces | Annually |
External Controls/Receptacles | Annually |
Internal Receptacles/Circuit Boards | Annually |
|
|
Performance Verification |
|
Refer to Initial Startup in the | Semiannually |
CTFLM/CTSLM User Manual |
|
|
|
9