APC SMC1000, SMC1500 Display interface features, 1000/1500 VA Description, 230 Vac, 120 Vac

Page 8

Display interface features

1000/1500 VA

1000/1500 VA

Description

120 Vac

230 Vac

 

 

 

 

 

On Line: The UPS is supplying conditioned AC power to connected equipment.

 

 

 

Green mode: The UPS is operating at the most efficient level by bypassing unused AVR components while acceptable AC voltage is present. The UPS will enter and exit Green mode automatically and will not compromise power protection.

Load Capacity: The load capacity percentage is indicated by the number of load bar sections illuminated. Each bar represents 20% of the load capacity.

Estimated Run Time / Min: This indicates the battery runtime minutes that remain if the UPS switches to battery power.

Battery Charge: The battery charge level is indicated by the number of load bar sections illuminated. When all five blocks are illuminated, the battery is fully charged. Each bar represents 20% of the battery charge capacity.

Overload: The equipment connected to the UPS is drawing more power than the voltage rating allows.

Event: The event counter indicates the number of events that occurred to cause the

UPS to switch to battery operation.

Automatic Voltage Regulation (AVR): The UPS has an AVR boost feature that automatically regulates low levels of input voltage without using battery power. The 230 Vac model has an additional AVR trim feature that regulates high levels of input voltage. When the 120 Vac AVR icon is illuminated, the UPS is compensating for low input voltage whereas with the 230 Vac, the following happen:

When illuminated, the UPS is compensating for low input voltage.

When illuminated, the UPS is compensating for high input voltage.

In: Input voltage.

Out: Output voltage.

System Faults: An internal system fault has occurred. The fault number will illuminate on the display. Refer to Display interface features on page 7.

Mute: An illuminated line through the icon indicates that the audible alarm is disabled.

Battery Fault: The icon will flash to indicate that the battery is disconnected.

When the icon remains continuously illuminated the UPS has failed a Self-Test or the battery is near the end of its service life and should be replaced.

Refer to LCD status indicators on page 6.

On Battery: The UPS is supplying battery backup power to the connected equipment.

Smart-UPS C 1000/1500 VA 120/230 Vac Tower

7

Image 8
Contents Smart-UPSC Product Description Safety and General InformationSpecifications Installation Product OverviewFront view Rear viewsOperation Connect equipment to the UPSPower saving LCD screen Sensitivity adjustment settingsLED status indicators Status IndicatorsDisplay panel features LCD status indicators Status LCD Icon Audible Alarms Audible Alarm TerminatesDisplay interface features 1000/1500 VA Description230 Vac 120 VacSeconds Status Feature Reference GuideSystem Faults Troubleshooting Battery Replacement ServiceUPS Model Replacement Battery Transport the unitTwo-Year Factory Warranty Terms of warrantySmart-UPS C 1000/1500 VA 120/230 Vac Tower Page APC Worldwide Customer Support EN 990-4493A 2012