Table 1-1a. Performance Specifications for Series 664xA1

Parameter

 

 

Agilent Model Number

 

 

 

 

6641A

6642A

6643A

 

6644A

6645A

Output Ratings

 

 

 

 

 

 

 

Voltage:

 

0 - 8 V

0 - 20 V

0 - 35 V

 

0 - 60 V

0 - 120 V

Current:@ 40°C

 

0 - 20 A

0 - 10 A

0 - 6 A

 

0 - 3.5 A

0 - 1.5 A

Current:@ 50°C

 

0 - 18 A

0 - 9 A

0 - 5.4 A

 

0 - 3.2 A

0 - 1.4 A

Current:@ 55°C

 

0 - 17 A

0 - 8.5 A

0 - 5.1 A

 

0 - 3.0 A

0 -1.4 A

 

 

 

 

 

 

 

Programming Accuracy (@ 25 ± 5 °C)

 

 

 

 

 

 

Voltage: 2

0.06% +

5 mV

10 mV

15 mV

 

26 mV

51 mV

Current:

0.l5 % +

26 mA

13 mA

6.7 mA

 

4.1 mA

1.7 mA

 

 

 

 

 

 

Ripple & Noise (from 20 Hz to 20 MHz with outputs ungrounded, or with either output terminal grounded)

 

Constant Voltage:

rms

300 ∝V

300 ∝V

400 ∝V

 

500 ∝V

700 ∝V

Constant Voltage:

p-p

3 mV

3 mV

4 mV

 

5 mV

7 mV

Constant Current:

rms

10 mA

5 mA

3 mA

 

1.5 mA

1 mA

 

 

 

 

 

 

 

Readback Accuracy (from front panel or over GPIB with respect to actual output @ 25 ±:5 °C)

 

 

Voltage: 2

0.07% +

6 mV

15 mV

25 mV

 

40 mV

80 mV

+Current

0.15% +

18 mA

9.1 mA

5 mA

 

3 mA

1.3 mA

-Current

0.35% +

40 mA

20 mA

12 mA

 

6.8 mA

2.9 mA

 

 

 

 

 

 

 

Load Regulation (change in output voltage

or current for any load change within ratings)

 

 

Voltage

 

1 mV

2 mV

3 mV

 

4 mV

5 mV

Current:

 

1 mA

0.5 mA

0.25 mA

 

0.25 mA

0.25 mA

 

 

 

 

 

 

 

Line Regulation (change in output voltage

or current for any line change within ratings

 

 

Voltage:

 

0.5 mV

0.5 mV

1 mV

 

1 mV

2 mV

Current:

 

1 mA

0.5 mA

0.25 mA

 

0.25 mA

0.25 mA

 

 

 

 

 

 

 

 

Transient Response Time (for the output voltage to recover to its previous level (within 0.1% of the rated voltage or 20 mV, whichever is greater) following any step change in load current up to 50% of the rated current.

 

< 100 ∝s

AC Input Ratings (selectable via internal

switching - see Appendix C)

Nominal line voltage:

100, 120, 220, 240 Vac (-13%, +6 %)

 

Frequency:

230 Vac3 (-10%, +10%)

50/60 Hz

 

Output Terminal Isolation

±240 Vdc (maximum, from chassis ground)

Notes: 1For Supplemental Characteristics, see Table 1-1b.

2Specification may degrade slightly when unit is subjected to an RF field ≥ 3V/meter. 3For 230Vac operation, unit is internally set to 240Vac

16 General Information

Image 16
Contents Operating Guide Gpib DC Power Supplies Agilent Part No Microfiche Part No JanuaryWarranty Limitation of WarrantyCertification Exclusive RemediesSafety Summary GeneralSafety Symbol Definitions Symbol DescriptionPrinting History HerstellerbescheinigungDeclaration of Conformity Manufacturer’s Name and Address6x4yA6x5yAE435xA.b.11.24doc.doc 6x4yA6x5yAE435xA.a.11.24doc.doc Table of Contents Controller Connections Connecting Series 667xA Power Supplies to the LoadIntroduction Getting Acquainted Programming the Output Introduction Equipment Required General Procedure Option 601 Installation 135 Option 602 Installation 136Front Panel Calibration Calibration Over the Gpib 100General Information IntroductionQuick Document Orientation Topic LocationInstrument Identification Safety ConsiderationsOptions Accessories Family Power Agilent ModelsDescription Support rails E3663AC are requiredRemote Programming Front Panel ProgrammingAnalog Programming Output Characteristic Specifications and Supplemental CharacteristicsSeries Specifications Characteristics GeneralOutput Ratings Voltage Current@ 40CCurrent@ 50C Current@ 55CAverage Resolution Voltage Temperature Coefficients change per C VoltageMaximum Input Power Output Programming Range maximumAuto-Parallel Configuration Analog Programming IP & VP Input SignalMaximum AC Line Current Ratings Vac nominal Maximum Reverse Bias CurrentDigital Port Characteristics Safety Compliance Complies withDimensions Width Gpib Interface CapabilitiesOutput Impedance Curves Typical General Information 50 a 25 a 15 a 51.188 a 25.594 a 15.356 a 214 a 095 a Rms 15 AM fuse Digital Port Characteristics Output Impedance Curves Typical General Information Voltage 04% + Current0 . l % + Current@ 0 to 55C±Current Typical Resolution Voltage Maximum Input VA and Power±Current Readback Analog Programming ±IP Current Monitor +IMAnalog Programming IP & VP Input Signal VP Input Impedance IP to -IP Differential Input SignalCurrent Monitor Output +IM Output Signal Full-load programming speed up/down time time forWeight Net Output Characteristic Curve General InformationOutput Impedance Curves Typical General Information Output Ratings Voltage Current VP Input Signal + IP Input SignalCurrent Monitor IM Output Signal Typical Common Mode Noise Current Rms Peak-to-peakMaximum Reverse Voltage Current Sink Capability Maximum AC Line Current Ratings Range Rms line currentLine fuse Range Rms line currentDesigned to comply with Maximum memory write cyclesHeight Output Impedance Curves Typical Milliohms440 a 220 a 110 a Derated linearly 1%/C from 40 C to Max Power 6.67KW Voltage Overvoltage Protection OVP Typical Resolution VoltageDrift Temperature Stability Temperature Coefficients change per C9000 VA Output Characteristic Curve Vout Agilent 6691A Agilent 6690AAgilent 6692A Supplemental Gpib Characteristics for All Models Parameter Operator Replaceable Parts List Description Agilent Part NoOperator Replaceable Parts List Description Agilent Part No Installation InspectionDamage Packaging Material Items SuppliedLocation and Temperature CleaningTemperature Performance Bench OperationInstalling the Series 664xA and 665xA Power Cord Input Power SourceInstalling the Series 667xA Power Cord Connecting the Series 667xA Power Cord Installing the Series 668xA Power Cord Series 668xA/669xA Overall Wiring DiagramInstalling the Series 669xA Power Cord Connecting the Series 668xA Power CordConnecting the Series 669xA Power Cord Page Introduction Preliminary Checkout All Models Turn-On CheckoutTurn-On Checkout Power-On Checkout All Models Using the Keypad All ModelsOutput Checkout All Models Shifted KeysOpen or Connected to a Voltmeter Checking the Voltage FunctionPress Prot Clear Checking the Current Function Checking the Save and Recall Functions All Models Determining the Gpib Address All ModelsCase of Trouble Line FuseSeries 664xA and 665xA Supplies Series 667xA SuppliesError Messages All Models Selftest ErrorsPower-On Error Messages Series 668xA SuppliesChecksum Errors Runtime Error MessagesPower-On Selftest Errors Display Failed Test Error Display Failed TestUser Connections Load Wire Selection All ModelsRear Panel Connections All Models Digital Connector All Models Analog Connector All ModelsPin No Fault/Inhibit Digital I/O Output Isolation Load ConsiderationsCapacitive Loads 6651A 6652A 6653A 6654ABattery Charging Local Voltage SensingInductive Loads 6641A 6642A 6643A 6644A 6645A 6651A 6652A 6653A 6654A 6655ARemote Voltage Sensing Connecting One Supply to the Load StabilityConnecting Supplies in Auto-Parallel Program Slave 2 OVP to the Maximum Level Enable OCP on the MasterInsert Protection Diodes Wiring Considerations Connecting Supplies in SeriesExternal Voltage Control Connecting Series 667xA Power Supplies to the Load Programming4a. Series 667xA Rear Panel Output Connections 6671A 6672A 6673A 6674A 6675A Connecting the Sense Leads Connecting One Power Supply to a Single Load Connecting One Power Supply To Multiple LoadsConnecting Supplies in Auto-Parallel 4f. Series 667xA Series Connection Remote Sensing Optional Wiring Considerations -4g 4g. Series 667xA Analog Programming ConnectionsConnecting Series 668xA and 669xA Power Supplies to the Load Local Voltage Sensing Load Leads Remote Sense PointsInstructions supplied with the kit Connecting Supplies in Auto-Parallel Connecting Supplies in Series 5g. Series 668xA and 669xA Analog Programming Connections Stand-Alone Connections Controller ConnectionsLinked Connections Controller Connections Getting Acquainted Front Panel OperationFront Panel Operation Display Status AnnunciatorsUnr DisFront Panel Controls and Indicators Output Rotary Controls VoltageSystem Keys Function KeysLine Switch On / Off Programming the OutputEstablishing Initial Conditions Entry Keys Thru Press to select numerical valuesProgramming Voltage Setting the OVP LevelProgramming Overvoltage Protection Checking OVP Operation Programming CurrentClearing The OVP Condition CV Mode vs. CC Mode Setting The OCP ProtectionProgramming Overcurrent Protection Checking OCP OperationSaving and Recalling Operating States Unregulated OperationTurn-On Conditions Setting the Gpib Address Types of Power Supply Gpib AddressesChanging the Power Supply Gpib Address Action Display ShowsPage General Procedure CalibrationEquipment Required Parameters CalibratedFront Panel Calibration Series 668xA/669xA Setup Figure A-1. Calibration Test SetupEnabling the Calibration Mode PASWDl Entering Voltage Calibration ValuesCalibrating the OVP Trip Point Entering Current Calibration ValuesCalibration Error Messages Recovering From Calibration ProblemsTable A-3. Gpib Calibration Error Messages Meaning Calibration Over the Gpib Front Panel Corresponding Scpi CommandCalibration Language Dictionary Command Syntax CALibrateSAVE Parameters None Examples Command SyntaxCalcurrmon Series 668xA/669xA only Calvolt Agilent Basic Calibration ProgramFigure A-2. Agilent Basic Calibration Program 570 ! Line 590 Password Must be Edited for Model Other than Steps 640 Through 670 not Used on 664x, 665xOperation Verification Test Equipment RequiredList of Equipment Current Monitoring ResistorFigure B-1. Verification Test Setup Performing the Tests Current Programming and Readback Accuracy Sufficient size to carry the maximum rated currentModel Agilent 6641A Voltage Programming and Readback Current Programming and ReadbackModel Agilent 6642A Voltage Programming and Readback Model Agilent 6643A Voltage Programming and ReadbackModel Agilent 6645A Voltage Programming and Readback Model Agilent 6651A Voltage Programming and Readback Model Agilent 6652A Voltage Programming and ReadbackModel Agilent 6653A Voltage Programming and Readback Model Agilent 6654A Voltage Programming and ReadbackModel Agilent 6655A Voltage Programming and Readback Model Agilent 6671A Voltage Programming and Readback Model Agilent 6672A Voltage Programming and ReadbackModel Agilent 6673A Voltage Programming and Readback Model Agilent 6674A Voltage Programming and ReadbackModel Agilent 6675A Voltage Programming and Readback Model Agilent 6680A Voltage Programming and Readback Model Agilent 6681A Voltage Programming and ReadbackModel Agilent 6682A Voltage Programming and Readback Model Agilent 6683A Voltage Programming and ReadbackModel Agilent 6684A Voltage Programming and Readback Model Agilent 6691A Voltage Programming and Readback Model Agilent 6690A Voltage Programming and ReadbackModel Agilent 6692A Voltage Programming and Readback Page Line Voltage Conversion Series 664xA and 665xA Power SuppliesLine Voltage Conversion Series 667xA Power Supplies Figure C-2. Series 665xA Line Select JumpersSeries 668xA/669xA Power Supplies Figure C-4. Removing the Series 668xA/669xA Inner Cover Fault/Inhibit Operation Digital ConnectorDigital Port Functions Figure D-2. Example of Inhibit Input Figure D-3. Examples of FLT Outputs Changing the Port Configuration Digital I/O OperationIN/OUT 2 pin Common pinRelay Link Operation CommonPage Function of Loop Compensation Current Loop Compensation Series 668xA OnlyCurrent Loop Compensation Series 668xA Only Current Loop Compensation Series 668xA Only Current Loop Compensation Series 668xA Only Setting the Loop Compensation Switch Figure E-1. CC Loop Compensation Curves For Model 6684AAutoparallel Procedure Using Agilent 668xA Series Power Supplies in Autoparallel Figure F-1 Master/Slave Current DivisionOption 601 Installation Output Bus Bar OptionsOption 602 Installation Bus Bar Spacer, 5040-1699Minus Bus Bar Plus Bus Bar Customer bus rails Output Bus Bar OptionsIndex IndexGpib 6665xA, 24 667xA, 29 668xA, 34 669xA, 39 output isolation Index United States Latin America Canada Australia/New ZealandEurope Asia Pacific JapanManual Updates
Related manuals
Manual 70 pages 51.66 Kb Manual 67 pages 46.05 Kb

668xA, 669xA, 667xA, 664xA, 665xA specifications

Agilent Technologies has long been a pioneer in the production of high-performance electronic test and measurement instruments, particularly in the field of power sources. Among its notable offerings are the Agilent 667xA, 669xA, 665xA, 664xA, and 668xA series of power supplies. These instruments are designed to provide stable, reliable power for a variety of applications, including electronic testing, industrial processes, and research laboratories.

The Agilent 667xA series is characterized by its programmability and advanced measurement functions. These power supplies support a wide range of output voltages and currents, allowing for flexible configurations that cater to different testing needs. The built-in measurement capabilities enable users to monitor the voltage, current, and power with high precision, which is essential for ensuring optimal performance in electronic applications.

The Agilent 669xA series stands out with its high-power outputs, making it suitable for demanding applications. These power supplies deliver high voltage and current levels, making them ideal for testing high-performance devices, such as power amplifiers and motor drives. Additionally, the 669xA series includes features such as overvoltage protection and complex output sequencing to enhance the safety and reliability of the testing process.

The Agilent 665xA and 664xA series focus on delivering high accuracy and excellent regulation. These models are particularly known for their low noise operation, which is critical for sensitive applications where precision is paramount. The integrated programming capabilities allow users to automate testing sequences, thus improving efficiency in research and development settings.

The 668xA series features advanced digital signal processing that enhances the precision and stability of the output. Users benefit from features like remote sensing and monitoring, allowing feedback adjustments that maintain output accuracy despite cable losses. Furthermore, the 668xA models can integrate seamlessly with various test environments thanks to their LAN, GPIB, and USB connectivity options.

Overall, the Agilent 667xA, 669xA, 665xA, 664xA, and 668xA power supplies provide a comprehensive range of solutions for diverse electronic testing needs. With their advanced features, superb measurement capabilities, and robust performance, these instruments empower engineers and researchers to conduct their work with confidence, precision, and efficiency.