SERVICE
In the unlikely event a HyTRON battery fails to deliver acceptable performance, it must be returned to the Anton/Bauer Customer Support Department, the only facility qualified and equipped to service the InterActive 2000 HyTRON batteries and calibrate the electronic components and sensors. Any attempt by the user or any other unauthorized persons to service this battery will surely result in improper calibration of the electronic components resulting in severe battery damage and/or safety hazards to the operator, in addition to voiding any/all remaining unconditional or
Therefore:
1.DO NOT attempt to service this battery under any circumstances.
2.DO NOT send this battery for service to anyone other than the Anton/Bauer Service Department.
3.DO NOT rebuild this battery - At the end of its useful life contact the Anton/Bauer Service Department.
SPECIFICATIONS
| HYTRON 140 | HYTRON 100 | HYTRON 50 | |||
|
|
|
| |||
OUTPUT VOLTAGE | 14.4v Nominal | 14.4v Nominal | 14.4v Nominal | |||
| 12 ~ 16.8v Operating | 12 ~ 16.8v Operating | 12 ~ 16.8v Operating | |||
CAPACITY | 140 WH Nominal | 100 WH Nominal | 50 WH Nominal | |||
(CELL CAPACITY) | (10 AH Rated) | (7 AH Rated) | (3.5 AH Rated) | |||
FUSE | 12.5amp/125volt | 12.5amp/125volt | Internal (7amp) | |||
RECOMMENDED OPERATION | ||||||
(MAXIMUM DISCHARGE RATE) | (175 watts) | (175 watts) | (75 watts) | |||
TYPICAL | @ 20w | – 7 hrs. | @ 20w | - 5 hrs. | @ 10w | - 5 hrs. |
| @ 25w | – 5.6 hrs. | @ 25w | - 4 hrs. | @ 20w | - 21/2 hrs. |
| @ 40w | – 3.5 hrs. | @ 40w | – 2.5 hrs. | @ 25w | - 2 hrs. |
WEIGHT | 5.5 lbs | 5.5 lbs | 1.9 lbs | |||
SIZE | 5 5/16 x 4 1/2 x 3 3/4 | 5 5/16 x 4 1/2 x 3 3/4 | 5 1/4 x 3 1/2 x 2 1/8 |