M-Systems Flash Disk Pioneers 45-SR-001-01-7L user manual Troubleshooting, Built-In Self Test

Page 15

FFD 3.5" SCSI Flash Disk User Manual

8 Troubleshooting

8.1Built-In Self Test

The FFD performs a self-test during power up. If the test fails, the green LED flashes at a rate of 1 Hz. If you encounter this problem, please contact your dealer or technical support.

8.2Common Problems

The following sections describe common problems and their causes.

8.2.1Installing Your SCSI Host Adapter

A SCSI host adapter is basically a standard PC board, regardless of the bus system used. For example:

To install a standard Adaptec 1542CF:

1.Check the default values of the board and verify that they do not conflict with other devices in the PC.

2.Check the I/O-address range, the IRQ(s), DMA channel, and the BIOS address for conflicts. When using a memory manager, exclude the selected BIOS address space from its memory pool. When selecting all resources, enter them in your list of resources.

3.Install the host adapter in the PC and power it ON. If you did not un-install the BIOS, a BIOS boot message similar to the following is displayed:

Adaptec AHA-2940 Ultra/Ultra W BIOS v1.23

(c) 1996 Adaptec, Inc. All Rights Reserved

<<< Press <Ctrl> <A> for SCSI Select (TM) Utility >>>

SCSI ID: LUN NUMBER #:# 0:0 – DEC DSP3085S-B SD16 – Drive C: (80h)

SCSI ID: LUN NUMBER #:# 1:0 – M-Systems FFD 350/FMAX 5D – Drive D: (81h)

The boot-up message lists all devices on the SCSI bus that are powered ON. Additionally, it indicates if any of the devices are disks that are supported by the BIOS.

4.Power OFF the PC and install the SCSI device(s). If you have more than one internal device:

Set up a unique SCSI ID (not 7) on each of the devices.

Select one of these devices to be at the end of the cable.

5.Make sure that the chosen device has its termination enabled and disable termination on all other devices. Termination is either enabled through one or more jumpers, or by installing or removing some resistor packs on the device’s PCB.

45-SR-001-01-7L REV 4.0

15 of 22

Image 15
Contents FFD 3.5 Scsi Flash Disk Table of Contents Kit Contents GeneralVisual Inspection Handling Instructions Scsi ID InstallationFFD 3.5 Scsi Drive Configuration System RequirementsTermination Write Protection Termination Power TrmpwrFFD 3.5 Scsi Flash Disk Drive Installation Installing the FFD in a PCTo install the FFD Scsi Cable Connection and Termination Configuration To install the FFD in a UNIX-based platform Using the FFD on a DOS-Based PlatformUsing the FFD on a UNIX-Based Platform To install the FFD as a disk drive under DOSTo install the FFD as a drive under Unix 209BFFH Drive Parameters3D68FFH F5AH Status LED Color Indicator Description LED Indicators and Configuration SwitchTo install a standard Adaptec 1542CF TroubleshootingCommon Problems Installing Your Scsi Host AdapterScsi ID Configuration Termination ConfigurationCables Solving Installation ProblemsUnstable Termination Incorrect TerminationGetting Help Frequently Asked Questions FAQs About Scsi What is Termination and TRMPWR? What is Plug-and-play P&P SCSI?What is Scsi Configured AutoMagically SCAM? What is a Scsi ID?Cables, Cable Lengths What types of Scsi connectors are available?Signal Levels What is Single-Ended and Differential SCSI?How to Contact Us