M-Systems Flash Disk Pioneers 45-SR-001-01-7L Termination Power Trmpwr, Write Protection

Page 7

FFD 3.5" SCSI Flash Disk User Manual

5.2.3Termination Power (TRMPWR)

Termination power must be supplied by at least one device on the SCSI bus; it is normally supplied by the host adapter. However, if you are unsure whether TRMPWR is available in your system, you can configure the FFD to supply TRMPWR. Note that several devices can supply TRMPWR without affecting overall system performance or causing damage to the drive (or any other device on the bus). If TRMPWR is not available in the system, this will lead to intermittent errors and other problems. TRMPWR is enabled by setting the DIP switches according to Table 3.

Table 3: Termination Power (TRMPWR) DIP Switch Settings

TRMPWR

Enabled

Disabled1

Switch 5

ON

OFF

1 Default factory setting

5.2.4Write Protection

The FFD has an internal active write protection option. The write protection (WP) is software implemented, and the switch value is retrieved during the FFD power cycle/bus [device] reset. Toggling the WP switch must be followed by a reset to activate the write protection option. Write

protection disables the FORMAT, WRITE, WRITE EXTENDED, WRITE BUFFER AND SECURITY ERASE

commands, but does not disable the security erase interrupt. It is enabled/disabled by setting the DIP switch as described in Table 4.

If an attempt is made to execute the disabled commands, a command returns in Check Condition status with a WP Sense Key.

The WP switch must be toggled before powering up the FFD.

Table 4: Write Protection DIP Switch Settings

Write Protect

Enabled

Disabled1

Switch 6

ON

OFF

1 Default factory setting

45-SR-001-01-7L REV 4.0

7 of 22

Image 7
Contents FFD 3.5 Scsi Flash Disk Table of Contents General Kit ContentsVisual Inspection Handling Instructions Scsi ID InstallationFFD 3.5 Scsi Drive Configuration System RequirementsTermination Write Protection Termination Power TrmpwrInstalling the FFD in a PC FFD 3.5 Scsi Flash Disk Drive InstallationTo install the FFD Scsi Cable Connection and Termination Configuration To install the FFD in a UNIX-based platform Using the FFD on a DOS-Based PlatformUsing the FFD on a UNIX-Based Platform To install the FFD as a disk drive under DOSTo install the FFD as a drive under Unix 209BFFH Drive Parameters3D68FFH F5AH Status LED Color Indicator Description LED Indicators and Configuration SwitchTo install a standard Adaptec 1542CF TroubleshootingCommon Problems Installing Your Scsi Host AdapterScsi ID Configuration Termination ConfigurationCables Solving Installation ProblemsUnstable Termination Incorrect TerminationGetting Help Frequently Asked Questions FAQs About Scsi What is Termination and TRMPWR? What is Plug-and-play P&P SCSI?What is Scsi Configured AutoMagically SCAM? What is a Scsi ID?Cables, Cable Lengths What types of Scsi connectors are available?Signal Levels What is Single-Ended and Differential SCSI?How to Contact Us