WX Technical Instructions
Photo 8
Photo 9
Photo 10
Photo 12
Step 8
Remove the two Phillips head screws hold- ing the wiper blade and remove the blade. Be careful not to break the plastic position- ing posts.
(See Photo 8)
Step 9
Empty out the waste toner and clean felts and foam with a vacuum or compressed air.
(See Photo 9)
NOTE: Be careful not to damage felts, foam or the mylar recovery blade, as this can cause leaks. If the felts or foam are damaged or worn, replace.
Step 10
Apply OPC protector felt to the drum shutter door. You will need to remove the cartridge from the fixture.
(See Photo10)
Step 11
Apply padding powder on wiper blade and reinstall.
NOTE: If you are going to use a new after- market drum, always replace wiper blade.
Step 12
Apply padding powder to the OPC drum and install. The big helical gear will go on the right side of the waste hopper. Install the drum axle only far enough to hold the drum against the wiper blade. Rotate drum so the wiper blade wipes the padding powder off the drum.
(See Photo12)
3
Notes
Step 13
Once again, remove the drum axle and the drum. Reinstall the primary charge roller then reinstall the drum and drum axle.
NOTE: When reinstalling the drum axle, the axle slides through the drum from the left side. Make sure you install the axle in the right way. The notched end of the axle goes on the large gear end.
Need help with a particular remanu- facturing problem?
Call the Technical Resource Center from 8am - 5pm PST: 800 394.9900