C H A P T E R 2
LaserWriter Select 310 Software
Setting System Parameters
This section describes the compatibility operators that set Level 1 system parameters.
checkpassword
Syntax | int checkpassword bool |
Definition This operator checks the validity of the current password. It returns true if int is equal to the current system administrator password. Otherwise, after delaying for one second, it returns false.
Standard value: 0
Error None
defaulttimeouts
Syntax | – defaulttimeouts job manualfeed wait |
Definition This operator returns the following values:
■default job
■manual feed
■wait timeout values Standard value: 0 60 40
Error stackoverflow
idlefonts
Syntax | – idlefonts mark font sxsy rot chars |
Definition | This operator pushes a mark followed by the integers that control idle |
| time scan conversion (see setidlefonts). An empty list of integers, that |
| is one with just a mark on the top of the operand stack, specifies that the |
| standard set of characters is to be scan converted. |
| Standard value: mark |
Error | stackoverflow |
pagecount
Syntax | – pagecount int |
Definition This operator returns the value of the system parameter PageCount. That is, it returns the number of pages that have been printed by the LaserWriter Select 310 printer.
There is no way to reset this value.
Error stackoverflow
Setting Compatibility Operators | 23 |