Toshiba TIC-LF232A specifications Wiring Precautions, About establishment environment

Page 6

TIC-LF232A

Wiring Precautions

(1)Be sure to use thick walled steel conduit (22mm) for signal and excitation cable wiring between the detector and converter. Use flexible conduit at the cable outlets of the detector and converter.

(2)Connect the grounding wire (IV wire 5.5mm² or more) to a good earth ground (100Ω or less ground resistance). Make the wire as short as possible. Do not use a common ground shared with other equipment where earth current may flow. An independent earth ground is recommended.

(3)The allowable cable lengths between the detector and converter for the separate type flowmeter depend on the electrical conductivity of the object fluid. See Figure 4 below.

(4)Digital output 1, digital output 2 to 4 , digital output 1 to 2 are insulated mutually.

 

300

 

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(m)

 

 

 

 

 

 

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

length

30

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cable

10

 

 

 

 

 

 

 

m

 

 

 

 

 

 

 

 

Allowable

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

3

5

10

20

30

50

100

200

 

 

Conductivity導電率〔μ(µS/cm)

 

 

LF130形、LF131形、

 

形検出器と接続の場合

(1)When combined withLF150.

 

 

 

 

LF470形検出器と接続の場合

 

 

 

 

(2)When combined with LF470.

 

 

 

 

Figure 4. Electrical Conductivity and Cable length

About establishment environment

Do not store or install the flowmeter:

Where there is direct sunlight.

Where excessive vibration or mechanical shock occurs.

Where high temperature or high humidity conditions exist.

Places where corrosive atmospheres exist.

Places submerged under water.

Place where there is sloped floor. To put the flowmeter temporarily on the floor, place it carefully with something, such as stopper, to support it so that the flowmeter will not topple over.

In areas like the following, there may be the case that infrared switches do not function correctly. (If these are unavoidable, use an appropriate cover.)

(1)Where unit (operation panel) is exposed to direct sunlight, reflection of light onto window pane and diffused light reflection.

(2)Where smoke and steam may occur.

(3)Where exposed to direct snow, ice or mud.

Ordering Information

1.When ordering the LF232 converter, refer to Tables 1 (Type Specification Code).

An entry must be made for each of the columns in each of these tables.

2.Measuring range

3.I/O function specifications.

4.Ordering scope:

Actual flow calibration data: (required or not)

5.Specification of combined detector

6.Other scope:

Specification other than standard items.

Consult a Toshiba representative before ordering.

6

Image 6
Contents Specifications Overall SpecificationsIntroduction Converter Specifications Dimension and Weights Communications signalConditions when power fails Output displayInstallation DimensionsExternal Wiring Diagram External ConnectionsWiring Precautions About establishment environmentSpecification Code for converters LF232 TIC-LF232

TIC-LF232A specifications

The Toshiba TIC-LF232A is an advanced inverter air conditioning system designed to optimize energy efficiency while delivering outstanding cooling performance. As part of Toshiba's commitment to innovation and sustainable technology, this model incorporates some of the latest advancements in climate control engineering.

One of the standout features of the TIC-LF232A is its inverter technology. Unlike traditional air conditioning systems that operate on a fixed speed, the inverter technology allows the compressor to adjust its speed based on the current cooling demand. This results in significant energy savings, as the system can maintain the desired temperature more consistently while using less electricity. This feature also contributes to a quieter operation, with reduced noise levels making it suitable for residential and commercial environments alike.

The TIC-LF232A boasts a high Energy Efficiency Ratio (EER) and Seasonal Energy Efficiency Ratio (SEER), indicating its ability to deliver effective cooling with minimal energy consumption. The incorporation of eco-friendly refrigerants further emphasizes Toshiba's commitment to environmental sustainability, ensuring that users not only save on energy bills but also reduce their carbon footprint.

In addition to energy efficiency, the TIC-LF232A is equipped with a range of advanced technologies designed to enhance user comfort and convenience. The system features a smart control system that allows users to manage their air conditioning remotely via a mobile app. This feature enables users to set schedules, monitor energy usage, and adjust temperature settings from anywhere, providing maximum flexibility and control.

Another key characteristic of the TIC-LF232A is its multi-zone capability. The system can simultaneously provide cooling to multiple rooms or areas, allowing for customized comfort in different spaces. This is particularly beneficial for larger homes or commercial buildings where individualized climate control is valuable.

The TIC-LF232A also prioritizes air quality with its integrated filtration system. It includes advanced filters that enhance indoor air quality by capturing dust, allergens, and other particles, promoting a healthier living environment.

Overall, the Toshiba TIC-LF232A stands out as a cutting-edge air conditioning solution that combines superior energy efficiency, innovative technologies, and user-centric features, making it a top choice for those seeking reliable and effective climate control solutions.