Toshiba 3 manual Direction Change with RX Input page 2, Connections for bipolar reference

Page 2

TOSHIBA G3 APPLICATION GUIDELINE 21.5

Direction Change with RX Input (page 2 of 2)

Connections for bipolar reference

TERMINAL STRIP

ST

CC

F

CC

RX CC

bipolar reference

Example programming for bipolar reference

Group

Parameter

New Value

UTILITY PARAMETERS

Blind Function Selection

1

UTILITY PARAMETERS

Frequency Setting Parameters Blind

1

FREQUENCY SETTING PARAMETERS

Frequency Priority Selection #1

3

FREQUENCY SETTING PARAMETERS

RX Terminal Standard or Adjustable

1

FREQUENCY SETTING PARAMETERS

RX Reference Setting Point #1

-100 (default)

FREQUENCY SETTING PARAMETERS

RX Point #1 Frequency

-60

FREQUENCY SETTING PARAMETERS

RX Reference Setting Point #2

100 (default)

FREQUENCY SETTING PARAMETERS

RX Point #2 Frequency

60

NOTE: Never connect the ‘CC’ terminal to ground.

*For additional assistance, please contact Toshiba at (800) 231-1412 and ask for inverter marketing

Image 2
Contents Connections for positive-only reference Direction Change with RX Input page 1Introduction Terminal StripExample programming for bipolar reference Direction Change with RX Input page 2Connections for bipolar reference