When using NetWare 5.1

Follow the installation procedure described in the instruction manual to ensure that the installation is done properly.

About expansion of optional RAID controller D

When you use Server Setup Tool to setup the server with RAID controller D (MR466), the [Detailed Setup] option may not setup right. To set RAID configuration details with Server Setup Tool, use the following procedure.

(1)When the message [Press <Ctrl><M> to Run MegaRAID Configuration Utility] is displayed during the server boot, press [Ctrl]+[M]. After MegaRAID Configuration Utility is started, set RAID configuration in detail, and select [Logical Drive]-[Advanced Menu]-[Write Policy], set [WRTHRU] to the array that is installed on the OS. For operation procedures about MegaRAID Configuration Utility, refer to MegaRAID User's manual.

(2)After setting RAID configuration details, insert the Server Setup Tool CD-ROM and the Startup Disk floppy disk in the CD-ROM drive and the floppy disk drive respectively, then restart the system to start the Server Setup Tool.

4/15

S00047-EN EH02 Rev. E

Image 4
Contents When using Windows NT Server Toshiba Magnia 510D Read-Me-First AddendumNetwork adapter setup When using Windows 2000 Server S00047-EN EH02 Rev. E Tape Attached to the CPU Heat Sink When attaching or removing the Scsi HDD/ Scsi devices About an accuracy of the Real-time-clock RTCComponents List Magnia 510DAbout the system Bios of MAGNIA510D Check your CPU Kit-LA’s maker S-Spec code by mark of CPUCheck System Bios revision by Post messages How to get the latest BiosInstall the CPU Kit-LA Case of using Windows2000To view CPU Stepping levels on your computer 11/15 S00047-EN EH02 Rev. E 12/15 S00047-EN EH02 Rev. E 13/15 S00047-EN EH02 Rev. E 14/15 S00047-EN EH02 Rev. E 15/15 S00047-EN EH02 Rev. E