Toshiba 1600XP operation manual Changeable Service Software compenents 251 Vref PhAdj

Page 76

B-4

1600XP Series Installation and Operation Manual

1600XP Command Parameters Table

Cmd

Description

Brief Description

Location Map

Example

Rqd Security

By

ID

on LCD

 

 

 

 

Level to change

 

 

Tab

Block

 

 

222

VOOV De-

Output Overvoltage Detection Level in percent-

Setting

OUT

110 %

Nonchangeable

User

 

Level*

age

 

 

 

Nonchangeable

Administrator

 

 

- Of rated output voltage which was configured

 

 

 

Changeable

Service

 

 

with Command ID215

 

 

 

 

 

 

 

 

 

 

 

 

 

224

Fo Syn Win-

Output Frequency Synchronization Window

Setting

OUT

1.0 Hz

Nonchangeable

User

 

dow*

 

 

 

 

Nonchangeable

Administrator

 

 

 

 

 

 

Changeable

Service

 

 

 

 

 

 

 

 

225

Fo Slew Rate

Output Frequency Slew Rate

Setting

OUT

10

Changeable

Service

 

 

 

 

 

 

 

 

226

Vout Adjust

Output Voltage Adjustment

Setting

OUT

0

Nonchangeable

User

 

 

- Can adjust up to +/- 5 increment of one in

 

 

 

Changeable

Administrator

 

 

order to increase or decrease output voltage to

 

 

 

Changeable

Service

 

 

compensate line voltage drop.

 

 

 

 

 

 

 

 

 

 

 

 

 

227

Iout 100%

Output Current 100% Amount

Setting

OUT

250

Changeable

Service

 

Amount

 

 

 

 

 

 

 

 

 

 

 

 

 

 

228

OOL Delevel

Output Overload Warning/Fault Detection Level

Setting

OUT

110

Changeable

Service

 

 

in percentage

 

 

 

 

 

 

 

 

 

 

 

 

 

229

OOL DeDelay

Output Overload Warning/Fault Detection De-

Setting

OUT

30

Changeable

Service

 

 

lay at 125% @25°

 

 

 

 

 

 

 

 

 

 

 

 

 

230

OOL ReLevel

Output Overload Warning Recovery Delay

Setting

OUT

105

Changeable

Service

 

 

 

 

 

 

 

 

231

OOL ReDelay

Output Overload Warning Recovery Delay

Setting

OUT

160

Changeable

Service

 

 

 

 

 

 

 

 

232

Vout Comp.

Output Voltage will be compensated according

Setting

OUT

20

Changeable

Service

 

Step

to this setup and current percentage

 

 

 

 

 

 

 

 

 

 

 

 

 

233

Vout Gain

Use this value to convert AD value to Actual

Setting

OUT

7987

Changeable

Service

 

 

Value

 

 

 

 

 

 

 

 

 

 

 

 

 

234

Vout Offset

Feedback Offset adjustment due to hardware

Setting

OUT

0

Changeable

Service

 

 

and software components

 

 

 

 

 

 

 

 

 

 

 

 

 

242

Iout Gain

At 240VAC use this value to convert AD VAlue

Setting

OUT

1131

Changeable

Service

 

 

to Actual Value

 

 

 

 

 

 

 

 

 

 

 

 

 

243

Iout Offset

Feedback Offset adjustment due to hardware

Setting

OUT

0

Changeable

Service

 

 

and software compenents.

 

 

 

 

 

 

 

 

 

 

 

 

 

251

Vref PhAdj

Time delay adjustment to sync the actual phase

Setting

OUT

-8

Changeable

Service

 

60Hz

of output and plotting.

 

 

 

 

 

 

 

 

 

 

 

 

 

254

Vref Amplitude

Calibrated no Load Output Voltage

Setting

OUT

246

Changeable

Service

 

 

 

 

 

 

 

 

Image 76
Contents 1600XP Series Page Product Use and Warranty Restrictions Qualified Personnel onlyUninterruptible Power System UPS Purpose Toshiba Customer Support CenterToshiba Customer Support Center Toshiba International CorporationPage Table of Contents Screen Tab Settings Optional MB Maintenance Bypass UnitsPreventive Maintenance/Parts Replacement Display and KeysAppendix a 1600XP Specifications External Layouts/Dimensions/Shipping WeightsIndex Iii Page Symbols General Safety InstructionsProhibited Symbol indicates do not take action Signal Words Regulatory Compliance StatementFCC Class a Notice EMC Directive Class a NoteEquipment Warning Labels Critical Fuse Sizing14 15 16 Important Safety Instructions 20 a45 a 60 a 80 a 100 a 125 a 144 Vdc 216 Vdc 288 VdcQualified personnel shall Qualified Personnel OnlyTo be performed by Qualified Personnel Only Inspection/Storage/Disposal InspectionUnpacking StorageInstallation Precautions UPSPage Operating Precautions Conductor Routing and GroundingUPS Connections Terminal BlockOutput Cabling for VoutWire Size and Tightening Torque Number KVA 10 kVA 14-18 kVA 22 kVA Lb.-in. NmOptional Battery Cabinet Connections UPS Model Battery Cabinet Mccb CapacityPower Backup Power ConditioningProduct Description Application and UseStatic-Bypass Stop operation Operating ModesOn-Line Run operation Battery Backup On batteries EPO Emergency Power Off FunctionBattery Low Voltage Tolerances Battery Backup Time and Discharge ProcessUPS Capacity Battery Recharging Model Vmax Vmin IchargeCommand Options Starting the UPS Stopping the UPSFront Panel Layout Display and KeysDisplay Manual Controls 1600 XP Monitor and Settings screens Operating KeysRecords screens BATLight Emitting Diodes LED Status IndicatorsEnd Test Faults Operation Input Bypass Batt History Backup SystemTouchscreen Menu Tree Output DC Bus Ctrl/Cfg Disp/ReyeKeypad Controls Change Secu. LvlShift again Write keyScreen Security Passwords & Key Pad LoginScreen Tab Main RUN/Stop the UPSMimic Display Screen Tab MonitorMonitor Details Mimic Display Records Sample Record ScreensAudible Alarm Functions ConditionScreen Tab Settings Key Cmd ID range Types of ParametersDISP/REYE Block Changing UPS Parameter Settings No of Input Line 240VSettings Parameters Access Level Sec. AbbreviationUSR ADMRecalibrate the Touchscreen Calibration ScreenMA rms Vac peak MA peak Pin Signal Function Logic UPS Communication InterfacesRemote Contacts Current Vdc peak MA peakPin Symbol Description UPS LAN Shutdown Signal Operation18.3 RS-232C RemotEye III Network Card 18.5 EMDInternal Maintenance Bypass Optional MB Maintenance Bypass UnitsLED OFF External Maintenance Bypass Battery Pack Replacement Optional Receptacle Panel Installation Instructions System Protection Features UPS Protection SystemSystem Protection Functions Overheating Overcurrent Current Limit OverloadPreventive Maintenance/Parts Replacement Preventive MaintenanceCleaning the Touchscreen Overvoltage OvercurrentSystem Fault Messages Display Recrd Meaning ActionSystem Warning Messages Display Record Meaning ActionBsdv BtstflBypov BypuvSystem Mode Messages System Status MessagesDisplay Meaning Display Meaning ActionLansd PfailRmtsd RO2EEERRParts Replacement Batt AMB Temp Average LifetimeExternal Layouts/Dimensions/Shipping Weights Unit and Shipping WeightsDimensional Data Electrical Conduit Knock-out DataExternal Layout for 3.6kVA and 6kVA units Snmp Port Remote Eye Slot Standard Model 3.6 10 kva Appendix a 1600XP SpecificationsUnit Capacity 6kVA 3.1 kW KVA 5.1 kW KVA 6.8 kW KVA 8.5 kW Standard Models 3.6 10 KVA CONT’D Battery System Battery Replacement YuasaStandard Models 14 22 kva Capacity KVA 11.9 kW1 KVA 15.3 kW1 KVA 18.7 kW1Standard Models 14 22 KVA CONT’D Toshiba Part Number for 51896-FS 60995-FS Battery Pack Capacity KVA 11.9 kW1 KVA 15.3 kW1 KVA 18.7 kW 1Appendix B 1600XP Command Parameter Table On LCDTab Block ToshibaToshiba H3 NoneFierr OUTChangeable Service Software compenents 251 Vref PhAdj BYP Dcuv SW Dcov SWDcub SW BattChrgov RUN StopUSER, Admin AdminDvcoh ViovLansd On LCD Hist 707 Total VIUVs Total No. Of Input Undervoltage Settings 721 Total Sys Total No. of System Changes Settings Begin and end the user will be required to touch On LCD Page Appendix C 1600XP Dimensions and Weights KVA DimensionsKVA Dimensions w/ MBS KVA Dimensions 14 / 18 / 22 kVA Dimensions w/ Optional MBS Index RS232 Ascii A5 Page UPS Page Industrial Division
Related manuals
Manual 90 pages 35.4 Kb

1600XP specifications

The Toshiba 1600XP is an advanced multifunction printer that showcases Toshiba's commitment to innovation and reliability in office technology. Designed to meet the demands of modern businesses, the 1600XP integrates several features and technologies that enhance productivity while ensuring high-quality output.

One of the key characteristics of the Toshiba 1600XP is its impressive speed. Capable of printing up to 16 pages per minute, this printer is well-suited for busy work environments where efficiency is paramount. The first print-out time is remarkably fast, minimizing wait times and allowing users to get back to their tasks quickly.

In addition to its speed, the Toshiba 1600XP boasts exceptional print quality. With a high resolution of up to 1200 x 1200 dpi, it produces sharp, clear text and vibrant images, making it ideal for both document printing and professional presentations. The printer uses advanced laser technology, which contributes to consistent and reliable output over time.

The Toshiba 1600XP also integrates advanced scanning capabilities, allowing users to digitize documents with ease. It offers both color and monochrome scanning options, with various file formats available, including PDF and JPEG. The automatic document feeder (ADF) simplifies the scanning process by enabling batch scanning, increasing productivity for users who frequently digitize materials.

Connectivity options are a significant highlight of the Toshiba 1600XP. It comes equipped with USB and Ethernet interfaces, facilitating seamless integration into any office network. For organizations that value mobility, the printer also supports mobile printing solutions, allowing users to print directly from their smartphones or tablets using popular applications.

Energy efficiency is another important aspect of the Toshiba 1600XP. The device is designed to minimize power consumption without compromising performance. Toshiba has incorporated eco-friendly features that help businesses reduce their carbon footprint, making it a practical choice for environmentally conscious organizations.

In summary, the Toshiba 1600XP is a multifunction printer that excels in speed, print quality, and versatility. With its robust scanning capabilities, extensive connectivity options, and energy-efficient design, the 1600XP stands out as an outstanding solution for businesses looking to enhance their document management processes. Whether it's printing, scanning, or copying, the Toshiba 1600XP delivers excellent performance to meet the needs of any fast-paced office environment.