Siemens C79000-Z7076-C552-01 Improved Display and Print Functions, Working with DDB Files

Page 5

New Functions in Version V4.02

Improved Display and Print Functions

The changes to the display and print functions are listed below in detail, with a brief description of how each function can be used.

Function

Comment

 

 

Object names, for example, the

Menu command Options ￿ Customize;

description of a CPU can be

Option ªSave Object Names in the

stored in the programmable

Programmable Logic Controller.º

controller.

These object names are displayed when the

 

 

configuration is uploaded to the programming

 

device and during diagnosis (improved

 

overview).

 

 

Print preview possible

Menu command Station ￿ Print Preview

 

 

Address list can be printed

Menu command View ￿ Address Overview;

 

then click the ªPrintº button

 

Or, menu command Station ￿ Print; then

 

select the ªAddress Listº option.

 

 

Information on DDB files used is

When the station configuration is printed,

also printed

details relating to the DDB file for each of the

 

DP slaves are also printed; for example,

 

revision, revision number, DDB revision,

 

firmware release, hardware release.

 

 

Switching to Network Configuration

You can use the new menu command Options ￿ Configure Network to switch to the application for network and connection configurations.

Working with DDB Files

The original procedure for supplying STEP 7 with new device database (DDB) files has been improved. You can now use the menu command Options ￿ Install New DDB Files and the subsequent dialog boxes to locate the DDB file you require.

Another new feature in STEP 7, version 4.02 and above, is that type files (DDB files (.GSD)) and DP slave symbols (bitmaps) are now also stored in a project. When you configure a new station, you can refer back to the type/DDB files and symbols which were used to create another project (for example, on another programming device). The new menu command Options ￿ Import Station DDB Files enables you to do this.

The menu command for updating the hardware catalog is now Options ￿ Update Catalog, rather than Options ￿ Update DDB Files.

Supplement to the STEP 7 User Manual V4.0

5

C79000-Z7076-C552-01

Image 5
Contents Copyright 1998 by Siemens AG C79000-Z7076-C552-01 New and Modified Functions in Version Additional Settings in the Simatic Manager Improved Copy Function New CPU ParametersWorking with DDB Files Switching to Network ConfigurationImproved Display and Print Functions Configuring the ET 200X BM 147/CPU as a DP Slave Configuring the DP/PA Link Profibus Configuring Software RedundancyCreating a Catalog Profile More Convenient Way to Download Hardware ConfigurationsConfiguring Connections while Configuring a Network No Distinction Between Upper and Lower Case Characters Connecting an S7-200 to the Multipoint InterfaceEffects on Existing Programs New Functions in Version Additional Functions OperationPrinting Messages New Menu Command Filter and DisplayAssigning Value Ranges for Message Numbers Debugging User Programs Debugging in Program Status ProcedureNew Functions Forcing with S7-300 Modules Archiving Projects with ªLongº File Names Support for Archive Program JAR 1.02 and Winzip Batch ModeNew Function Diagnosing Hardware ± Quick View Improved Print Functions in the Simatic Manager New Functions in Version