New Functions in Version V4.02

3

Configuring Hardware

New CPU Parameters

There are many new components in version 4.02; for example, racks, C7 control systems, or CPUs in the hardware catalog. It is not possible to list all the updates or changes within the scope of this supplement; instead, only the new CPU parameters (which are relevant to the operation of the latest CPUs) are covered:

CPU Parameter

Remarks

 

 

Test operation/

Can be set in the ªProtectionº tab.

process operation

In process operation, debugging functions such as ªprogram

(see also

statusº or ªmonitoring/modifying variablesº are limited to

Chapter 9)

prevent the permissible increase in the scan cycle time from

 

being exceeded. For example, call conditions are not

 

permitted in the program status, and the status display for a

 

programmed loop is aborted on return.

 

It is not possible to debug with breakpoints in process

 

operation, nor can you execute a program step-by-step.

 

In test operation, all programming device/PC debugging

 

functions can be used without restriction, including those

 

which result in increases in the scan cycle time.

 

 

Protection level

Can be set in the ªProtectionº tab. Write access, and read

 

and write access to the CPU can be made dependent on the

 

use of a password. The password is set in this tab.

 

 

Improved Copy Function

If you hold the CTRL key down and select several modules or DP slaves, you can then paste these modules/DP slaves at another location.

Before pasting copied DP slaves, you must select the DP master system to which the DP slaves are to be ªattached.º

4

Supplement to the STEP 7 User Manual V4.0

C79000-Z7076-C552-01

Image 4
Contents Copyright 1998 by Siemens AG C79000-Z7076-C552-01 New and Modified Functions in Version Additional Settings in the Simatic Manager New CPU Parameters Improved Copy FunctionImproved Display and Print Functions Switching to Network ConfigurationWorking with DDB Files Configuring the ET 200X BM 147/CPU as a DP Slave Configuring the DP/PA Link Configuring Software Redundancy ProfibusMore Convenient Way to Download Hardware Configurations Creating a Catalog ProfileConfiguring Connections while Configuring a Network Connecting an S7-200 to the Multipoint Interface No Distinction Between Upper and Lower Case CharactersEffects on Existing Programs New Functions in Version Operation Additional FunctionsAssigning Value Ranges for Message Numbers New Menu Command Filter and DisplayPrinting Messages Debugging in Program Status Procedure Debugging User ProgramsNew Functions Forcing with S7-300 Modules New Function Diagnosing Hardware ± Quick View Support for Archive Program JAR 1.02 and Winzip Batch ModeArchiving Projects with ªLongº File Names Improved Print Functions in the Simatic Manager New Functions in Version