Siemens C79000-Z7076-C552-01 user manual Creating a Catalog Profile

Page 9

New Functions in Version V4.02

Creating a Catalog Profile

If the hardware catalog supplied with STEP 7 is too large or too difficult for you to use, you can create your ªownº catalog. In this way different catalog profiles are produced. The basis for each new catalog profile is the modules/components catalog with which you are already familiar. The profile of this catalog is known as ªstandard;º you are free to assign names of your own choice to the catalog profiles you create.

To create a new catalog profile, proceed as follows:

1.Select the menu command Options  Edit Catalog Profiles.

The application is opened with two catalog profiles: the ªStandardº profile and an ªemptyº profile containing no components.

2.Drag the required folders and modules from the standard profile window and drop them in the ªemptyº profile window. You can also adapt the structure to meet your requirements using the menu command Insert  New Folder.

3.Save the new catalog profile using the menu command File  Save As; choose a suitable name for the new profile.

The name of the new profile then appears in the ªProfileº list box in the ªHardware Catalogº window and can be selected.

Docking the ªHardware Catalogº Window on the Side of the Application Window

To prevent the ªHardware Catalogº window from obscuring the contents of the station window, you can ªdockº it on one side of the application window. Simply double-click on the area above the ªProfileº list box in the ªHardware Catalogº window. To release the ªdockedº window, double-click on this area again.

You can change the size of the ªHardware Catalogº window when it is in the ªundockedº state.

A More Convenient Way to Download Hardware Configurations

If you select the function PLC  Download and follow the dialog boxes, you can execute the following actions with a programming device:

Switch the CPU to STOP mode

(if the mode selector is set to RUN-P)

Compress memory

(if insufficient contiguous free memory is available)

Set the CPU to RUN

Supplement to the STEP 7 User Manual V4.0

9

C79000-Z7076-C552-01

Image 9
Contents Copyright 1998 by Siemens AG C79000-Z7076-C552-01 New and Modified Functions in Version Additional Settings in the Simatic Manager Improved Copy Function New CPU ParametersSwitching to Network Configuration Improved Display and Print FunctionsWorking with DDB Files Configuring the ET 200X BM 147/CPU as a DP Slave Configuring the DP/PA Link Profibus Configuring Software RedundancyCreating a Catalog Profile More Convenient Way to Download Hardware ConfigurationsConfiguring Connections while Configuring a Network No Distinction Between Upper and Lower Case Characters Connecting an S7-200 to the Multipoint InterfaceEffects on Existing Programs New Functions in Version Additional Functions OperationNew Menu Command Filter and Display Assigning Value Ranges for Message NumbersPrinting Messages Debugging User Programs Debugging in Program Status ProcedureNew Functions Forcing with S7-300 Modules Support for Archive Program JAR 1.02 and Winzip Batch Mode New Function Diagnosing Hardware ± Quick ViewArchiving Projects with ªLongº File Names Improved Print Functions in the Simatic Manager New Functions in Version