3 Locating the serial number
TABLE 2 | System Status LEDs |
|
|
Location | Indicator | Color | Description |
|
|
|
|
| Power | Green | Off - no power |
|
|
| On - power is on |
|
|
|
|
| Status | Green/Amber | Off - Switch is off |
|
|
| Green - OK |
|
|
| Amber - |
|
|
| or reset state |
|
|
| Blinking (green/amber alternating) - error |
|
|
|
|
| CMC Management | Blue/Amber | Steady blue - Normal/Stack Master |
|
|
| Flashing blue - Module identify |
|
|
| Steady amber - Not used |
|
|
| Flashing amber - Fault |
|
|
| Off - on fault/Stack Slave |
|
|
|
|
Port status LEDs
The following table provides descriptions of the port status LEDs on the front panel of the switch module.
TABLE 3 | CEE and FC port status LEDs |
| |
Location | Port type | Color | Description |
|
|
|
|
| CEE ports | Off - no link or unlicensed | |
|
| green/amber | Steady green - link is present |
|
|
| Flashing green - activity over the link |
|
|
| Steady amber - fault |
|
|
|
|
| FC ports | Off - no link | |
|
| green/amber | Steady green - link is present |
|
|
| Flickering green - normal activity |
Slowly flashing green - segmented
Rapidly flashing green - loopback
Steady amber - no sync
Slowly flashing amber - disabled
Rapidly flashing amber - fault
Locating the serial number
Before contacting service support, be sure to obtain the module’s serial number. Use one of these methods to locate the number:
•Use the switch module CLI and enter the ChassisShow command. The converged network switch serial number is displayed along with other data.
•Locate the serial number on the label attached to the converged network switch. Refer to Figure 2 on page 5 for location.
24 | Dell |
|