Cooper Bussmann dimensions 6125TD Series, Time Delay

Page 1

BrickFuses

6125TD Series, Time Delay

Description

Time Delay surface mount fuse capable of replacing glass tube fuses in certain applications

Environmentally rugged, complies with EIA-IS-722 Standard

Solder Immersion Compatible

Targeted for Consumer Electronics

ELECTRICAL CHARACTERISTICS

% of Amp Rating

Opening Time

100%

4 Hours Minimum

200%

1 Second Minimum

200%

2-4 Seconds Typical

200%

60 Seconds Maximum

Agency Information

UL Recognition Guide & File numbers: JDYX2 & E19180.

CSA Component Acceptance: 053787 C 000 & Class

No: 1422 30.

Environmental Data

Life Test: MIL-STD-202, Method 108A, Test Condition D

Load Humidity: MIL-STD-202, Method 103B

Moisture Resistance: MIL-STD-202, Method 106E

Thermal Shock: MIL-STD-202, Method 107D, air-to-air

Case Resistance: EIA/IS-722

Resistance to Dissolution of Metallization: ANSI J-STD-002, Test D

Mechanical Shock: MIL-STD-202, Method 213B, Test Condition A

High Frequency Vibration: MIL-STD-202, Method 204D, Test Condition D

Resistance to Solvents: MIL-STD-202, Method 215A

Dimensions mm(inches)

Land Pattern

Soldering Method

2.63.0

(0.102) (0.118)

4.0

(0.157)

8.6

(0.338)

Ordering

• Specify product code and packaging code

Wave Immersion: 260°C, 3 sec max.

Infrared: 260°C, 30 sec max.

SPECIFICATIONS

Product

Voltage

Interrupting

 

DC Cold

 

Typical

Typical

Code

Rating

 

Rating*

Resistance** (ohms)

Melting

Voltage

 

AC

DC

125VAC

60VDC

min.

 

typ.

max.

I2t†

Drop‡

6125TD500mA

125V

 

60V

50A

50A

.3350

 

.4025

 

.4700

0.716

245 mV

6125TD750mA

125V

 

60V

50A

50A

.2000

 

.2350

 

.2700

1.07

250 mV

6125TD1A

125V

 

60V

50A

50A

.1350

 

.1680

 

.2000

2.88

256 mV

6125TD1.5A

125V

 

60V

50A

50A

.0550

 

.0630

 

.0700

2.35

125 mV

6125TD2A

125V

 

60V

50A

50A

.0380

 

.0480

 

.0580

9.45

133 mV

6125TD2.5A

125V

 

60V

50A

50A

.0280

 

.0350

 

.0420

16.2

130 mV

6125TD3A

125V

 

60V

50A

50A

.0225

 

.0263

 

.0300

15.3

97 mV

6125TD3.5A

125V

 

60V

50A

50A

.0170

 

.0195

 

.0220

14.5

95 mV

6125TD4A

125V

 

60V

50A

50A

.0160

 

.0185

 

.0210

38.8

106 mV

6125TD5A

125V

 

60V

50A

50A

.0115

 

.0133

 

.0150

34.4

100 mV

6125TD7A

125V

 

60V

50A

50A

.0073

 

.0087

 

.0100

90.2

99 mV

*AC Interrupting Rating (Measured at designated voltage, 100% power factor); DC Interrupting Rating (Measured at designated voltage, time constant of less than 50 microseconds, battery source)

**DC Cold Resistance (Measured at 10% of rated current)

T ypical Melting I2t (Measured with a battery bank at rated DC voltage, 10x-rated current (not to exceed IR), time constant of calibrated circuit less than 50 microseconds)

T ypical Voltage Drop (Measured at rated current after temperature stabilizes)

Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at elevated ambient temperatures.

Image 1
Contents 6125TD Series, Time Delay Piece sample Packaging Code DescriptionStandard Package This is an insert Requirement Telecom Circuit ProtectorTime Current Curve 1025T500mA 250VAC 125VDC Min Typ Max I2t† Drop‡ 1025T250mA1025T800mA 1025T1ATime Current Curve Packaging Code Brick Fuses 1025T Series Time Lag, Low Breaking Capacity1025F500mA 250VAC 125VDC Min. typ. max I2t† Drop‡ 1025F250mA1025F800mA 1025F1ATime in Seconds Brick Fuses 1025F Series Fast Acting, Low Breaking Capacity6125FA Series, Fast Acting Piece sample 1025FA Series, Fast Acting SP1 1025TD Series, Time Delay OC-2537 Rev. XH 5/03 TCP TM Table of Contents Section Title Scope Catalog Symbol and Part Numbering SystemManufacturer and Production Facility TCPTCP2A Mechanical SpecificationsDimensions drawings not to scale End View mm Inches Electrical Specifications 050 075 100 Total Clearing I 2t ∝Sec Time Current Curve Page Page USA Marking SpecificationSoldering Method Land Pattern Temperature Derating CurveProcess Flow Chart Packaging SpecificationEnvironmental Reliabilitiy / Qualification Data