Brick™ Fuses
1025TD Series, Time Delay
Description
•Surface Mount
•Environmentally rugged, satisfies the
•Solder Immersion Compatible
•Targeted for Consumer Electronics
ELECTRICAL CHARACTERISTICS
% of Amp Rating | Opening Time |
100% | 4 Hours Minimum |
200% | 1 Second Minimum |
200% | 60 Seconds Maximum |
250% * | 10 Seconds Maximum |
Dimensions mm⁄(inches)
Drawing Not to Scale
*If fuse does not open @ 200% in 60 seconds, raise current to 250% and the fuse must open in 10 seconds maximum.
Agency Information
•UL Recognition Guide & File numbers: JDYX2 & E19180 (250mA - 5A)
•CSA Component Acceptance:
File # 053787 C000, Class # 1422 30
Environmental Data
•Life Test:
•Load Humidity:
•Moisture Resistance:
•Terminal Strength:
•Thermal Shock:
•Case Resistance:
•Resistance to Dissolution of Metallization: ANSI
•Mechanical Shock:
•High Frequency Vibration:
•Resistance to Solvents:
Land Pattern | 3.30 |
(0.130)
4.38
(0.172)
6.79
(0.267)
Ordering
• Specify product code and packaging code
Soldering Method
•Wave Immersion: 260°C, 10 sec max.
•Infrared: 260°C, 30 sec max.
SPECIFICATIONS
| Voltage | Interrupting | DC Cold | Typical | Typical | Marking | ||||
Product Code | Rating | Rating* | Resistance** (ohms) | Melting | Voltage | Code‡‡ | ||||
| AC | DC | 250VAC | 125VDC | Typical | I2t† | Drop‡ | 1st & 2nd | 3rd | |
1025TD250mA | 250V | 125V | 50A | 50A | 4.200 | 0.128 | 1900 mV | DD |
| |
1025TD500mA | 250V | 125V | 50A | 50A | 0.5500 | 1.47 | 455 mV | DF |
| |
1025TD750mA | 250V | 125V | 50A | 50A | 0.317 | 0.93 | 400 mV | DG |
| |
1025TD1A | 250V | 125V | 50A | 50A | 0.2030 | 9.91 | 387 mV | DH | U, | |
1025TD1.5A | 250V | 125V | 50A | 50A | 0.1025 | 11.79 | 310 mV | DK | ||
T | ||||||||||
1025TD2A | 250V | 125V | 50A | 50A | 0.0680 | 17.27 | 250 mV | DN | ||
or | ||||||||||
1025TD2.5A | 250V | 125V | 50A | 50A | 0.0420 | 16.51 | 201 mV | DO | ||
S | ||||||||||
1025TD3A | 250V | 125V | 50A | 50A | 0.0330 | 42.74 | 184 mV | DP | ||
| ||||||||||
1025TD3.5A | 250V | 125V | 50A | 50A | 0.0270 | 43.33 | 180 mV | DR |
| |
1025TD4A | 250V | 125V | 50A | 50A | 0.0220 | 66.96 | 152 mV | DS |
| |
1025TD5A | 250V | 125V | 50A | 50A | 0.0160 | 88.38 | 145 mV | DT |
|
*AC Interrupting Rating (Measured at designated voltage, 100% power factor random closing); DC Interrupting Rating (Measured at designated voltage, time constant of the calibrated circuit is less than 50 microseconds, battery source)
**DC Cold Resistance (Measured at ≤10% of rated current)
† T ypical Melting I2t (Measured with a battery bank at rated DC voltage,
‡T ypical Voltage Drop (Measured at rated current after temperature stabilizes) ‡‡ Marking Code - 3 rd (U = USA, T = Taiwan and S = China)
• Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at elevated ambient temperatures.