Liebert AccuVar, Type SS, LM Voltage Ratings and Power Source Configurations, Source Configurations

Page 6

Surge Suppression Systems

VOLTAGE RATINGS AND POWER SOURCE CONFIGURATIONS

Source Configurations

 

Nominal Operating Voltage

Maximum Continuous

Model Voltage Code

 

L-N

L-G

L-L

(Found in part number)

 

 

 

Single Phase L-N, 2 W + G

L

100

100

N/A

150 L-N

120 N or 120-

L

110

110

N/A

150 L-N

120 N or 120-

 

 

 

N

120

120

N/A

150 L-N

120 N or 120-

 

 

230

230

N/A

275 L-N

230 N or 230-

N

 

277

277

N/A

320 L-N

277 N or 277-

G

G

347

347

N/A

420 L-N

347 N or 347-

 

 

Single Phase L-L, 2 W + G

L1

N/A

208

208

130 L-L

208L or 208-

L1

 

 

N/A

240

240

150 L-L

240L or 240-

L2

L2

N/A

400

400

275 L-L

400L or 400-

N/A

480

480

275 L-L

480L or 480-

G

 

G

N/A

600

600

420 L-L

600L or 600-

 

Single Phase, 3 W + G

 

120

120

208, 240

150 L-N

120S

L1

L1

 

 

 

 

 

N

N

240, 277

240, 277

480

320 L-N

240S

L2

L2

 

 

 

 

 

G

G

347

347

600

420 L-N

347S

 

 

 

 

 

Three Phase Delta, 3 W + G

 

N/A

208

208

250 L-L

208D

A

 

N/A

240

240

320 L-L

240D

 

 

 

 

N/A

380

380

580 L-L

400D

B

 

N/A

400

400

580 L-L

400D

 

N/A

415

415

580 L-L

400D

C

 

 

N/A

480

480

580 L-L

480D

 

 

G

 

N/A

600

600

580 L-L

600D

 

 

Three Phase Delta Hi Leg, 4 W + G

 

120/240/120

120/240/120

240

150 L-N

240N

B

 

 

 

 

 

 

 

A

 

240/480/240

240/480/240

480

250 L-N

480H

N

 

G

 

 

 

 

 

 

C

 

 

 

 

 

 

Three Phase Wye, 4 W + G

 

120

120

208

150 L-N

120Y

A

 

127

127

220

150 L-N

127Y

 

 

N

 

220

220

380

320 L-N

230Y

 

230

230

400

320 L-N

230Y

B

 

 

254

254

440

320 L-N

254Y

C

 

 

277

277

480

320 L-N

277Y

G

 

 

347

347

600

420 L-N

347Y

 

 

Three Phase Wye, 3 W + G No Neutral

 

N/A

120

208

150 L-G

120X

A

 

N/A

127

220

150 L-G

127X

 

 

 

 

N/A

220

380

320 L-G

230X

B

 

N/A

230

400

320 L-G

230X

 

N/A

254

440

320 L-G

254X

C

 

G

 

N/A

277

480

320 L-G

277X

 

 

N/A

347

600

420 L-G

347X

Installation, Operation and Maintenance Manual

4

 

Liebert TVSS Units SL-22085 Rev 2, 11/2006

Note 1: For other voltages or source configurations, consult factory.

Image 6
Contents Interceptor II, SAD Hybrid Advantage, Type SS, LM, AccuVar Page Surge Suppression Systems Storage Unpacking and Preliminary InspectionHandling Considerations Location ConsiderationsVoltage Ratings and Power Source Configurations Electrical ConnectionsVoltage Ratings and Power Source Configurations Source ConfigurationsTypical Parallel Connections with Internal Rotary Disconnect System Grounding and Bonding Preventative Maintenance Inspection and Cleaning Troubleshooting / Servicing / MaintenanceTroubleshooting ServicingType LM Series Installation InstructionsSurge Suppression Systems AccuVar SeriesPowerSure LPL Allowable RangeSeries Surge Protective Device SPD Installation Instructions Liebert Active Tracking Filter Series Type FLiebert Active Tracking Filter System GroundLiebert PanelGuard Series Type Lpge SPD Interconnect Assembly Installation Instructions Liebert AccuGuide Series Type ACGNational Electrical Code NEC Considerations Conduit Size ConnectionConduit Equipment PerformanceDimensional Information Hybrid Advantage Series Type H Alarm Enable/Disable FeatureAudible Alarm AccuVar Series AccuVar Series Type ACV & AIIModel Dimensions Inches Active Tracking Filter Series Type FModel Application Wire Range Type SS SeriesBreaker Size Type LM Series Unit Dimensions InchesWire Size Breaker Lbs750 000 PowerSure Medium Exposure Series Type LPM375 500 000PowerSure Low Exposure Series Type LPL PanelGuard Series Type Lpge Example Installations Surge Suppression Systems Limited Warranty Items Not Covered By Warranty LimitationsMiscellaneous Surge Suppression Systems Items Not Covered By Warranty Liebert Corporation

PanelGuard Extension, LM, Interceptor II, ATF Series, SAD Hybrid Advantage specifications

The Liebert AccuVar is a cutting-edge power management solution designed to optimize and protect critical infrastructure. This system is well-known for its unique ability to provide variable voltage and current, ensuring that equipment receives the right level of power needed for optimal performance. One of its main features is the capability for advanced energy management, which aids in reducing operational costs and improving energy efficiency. This is particularly beneficial in environments where power consumption is a major concern.

Another product in this domain is the PowerSure LPM/LPL Series. This series is specifically designed for high-performance applications, featuring a compact design that maximizes space efficiency without compromising on power quality. With excellent surge protection and state-of-the-art noise filtering technologies, the PowerSure series is perfect for protecting sensitive electronic equipment. Its real-time diagnostic capabilities allow users to monitor power quality continuously, which is crucial for both operational stability and preventative maintenance.

The Type SS is a reliable solution for mission-critical applications, featuring an advanced system architecture that ensures uptime and reliability. With high operating efficiency and low total harmonic distortion, the Type SS minimizes operational risk while enhancing system performance. Its modular design provides flexibility in scaling and upgrading systems according to the changing needs of the business.

The SAD Hybrid Advantage showcases a blend of traditional and innovative technologies, enabling an optimal balance between performance and reliability. This series employs a hybrid system that leverages both linear and switching technologies, offering superior load handling capabilities. Enhanced thermal management and intelligent control features ensure that the system operates efficiently, regardless of load variations.

Lastly, the ATF Series is engineered for robust protective capabilities and versatile application in challenging environments. With features such as integrated battery management and customizable configuration options, the ATF series is adaptable for various power needs. The system’s ease of installation and user-friendly interfaces make it highly accessible for IT and facility managers.

Overall, these power management solutions represent a significant leap forward in technology, offering businesses a wide range of features including efficiency, reliability, and adaptability in their power systems. Each series serves distinct applications, ensuring that there is a suitable solution for every critical infrastructure need.