OWNER’S MANUAL
PS220
SEQUENCING,
| PS220 | |
CH 1 | TWO CHANNEL | |
SEQUENCER | ||
|
ETA SYSTEMS
120 VAC |
| A Creative Light And Sound Company |
50/60 HZ |
|
|
20 AMPS |
| RESET |
TOTAL | PROTECTION ON |
POWER
SEQUENCING
Air Vents
LED Indicators
PS220 SPECIAL FEATURES:
• Power 120 VAC 50/60Hz, 20 amps total current available, |
and 2400 watts total power. |
• Sequences 2 outlets - CH 1 and CH 2 |
• Programmable delay between CH 1 and CH 2 turn off of |
1, 5, 10 and 30 seconds |
• Remotely turn “ON” or “OFF” the outlets. A remote LED |
indicator can be used to show the PS220 activity |
• Daisy chain capabilities using a communications port |
• Manual reset of the microprocessor |
CH 2
CH 1
CH 2
PS220:
Fan
• Spike and surge protection on all three legs of incoming |
120V 50/60Hz, |
• Surge protection is active when the green |
(PROTECTION ON) LED is lit. |
• Certified to UL1472 and CSA C22.2 No.184.1 standards |
SEQUENCING: When activated, the PS220 CH1 outlet turns “ON”, then CH2 outlet turns “ON”. When deactivated the PS220 CH2 turns “OFF”, then CH1 turns “OFF.”
DELAY: A 1, 5, 10 or 30 second
RESET: Use the push button switch for resetting the unit’s microprocessor. The Green “POWER ON” LED goes off for 1 second during a manual rest. Use the recommended screwdriver to depress the reset button.
UNIT OPERATION: A Green “POWER ON” LED will indicate when power is present to the unit. (The Green “POWER ON” LED will go off for 1 second during power up, to indicate the microprocessor is ready.) Green “POWER ON” LED will flash while the unit is sequencing on or off, or when another sequencer that is daisy chained in line is sequencing on or off. The two Red CH 1 and CH 2 LED indicators will light when CH1 or CH2 of the receptacle is turned on.
DAISY CHAIN: The PS220 is daisy chained to any other PS220 or
Master Unit: connection to the outputs only (terminals 6 & 7). This output connection is then connected to an input of another ETA sequencing unit.
Slave Unit: connection to the inputs only (terminals 4 & 5). This input connection comes from the output of another ETA sequencing unit.
Note: the
PS220
SEQUENCER BASE RELAY INSTALLATION OPTION
REMOTE
WALL
PLATE
2 or 3
WIRES
L.E.D. AND
SWITCH
| PS220 |
|
| 2 OR 4 CHANNEL |
| 2 CH SEQ |
|
| SEQUENCER |
| PS220 | 2 WIRES | PS220 | |
CH 1 | TWO CHANNEL | |||
ETA SYSTEMS | ||||
SEQUENCER |
|
|
| |
120 VAC |
|
|
| PD11SP |
50/60 HZ |
|
|
| |
TOTAL | PROTECTION ON |
|
| |
20 AMPS |
| RESET |
|
|
| POWER |
|
| PD420VS |
| SEQUENCING | OUT | IN | |
| CH 2 | |||
CH 2 | CH 1 |
|
|
|
*NOTE: Internal terminal block for
| 2 OR 4 CHANNEL |
| SEQUENCER |
2 WIRES |
|
PS220 | |
| PD11SP |
| |
OUT IN | PD420VS |
|
|
TERMINAL BLOCK
CONNECTION
1.Switch (+)
2.Switch & LED
3.LED (+) Indicator
4.Input
5.Input
6.Output
7.Output
|
| J100 |
|
10 SEC |
| 30 SEC | |
| |||
| |||
| |||
5 SEC |
|
| 1 SEC |
|
| ||
|
|
|
1 2 3 4 5 6 7
This is the PC board located inside insulating barrier
1PCB-086
You can change the delay by moving the jumper at J100.
Using the recommended wire, connect to the terminal block using one of the following two options. Recommended Wire: Size
Max. Wire Length 1000 FT. Screw