ETA Systems ETA-ECM30 specifications ECM Housing Types, ECM-RACEWY1 ECM-RACEWY3 ECM-RACEWY6

Page 7

ETA-ECM30

30A AC Power Module Spike Suppressor

ECM HOUSING TYPES

ECM-RACEWY1

ECM-RACEWY1

ECM-RACEWY3

ECM-RACEWY3

ECM-RACEWY6

The ETA-ECM30 requires an electrical housing. These housings are manufactured by Atlas Sound and are available through ETA Systems. The ECM-RACEWY1 holds 1 ECM module, the ECM-RACEWY3 holds up to three ECM modules, and the ECM-RACEWY6 holds up to six ECM modules. Three standard ¾" and 1" electrical knockouts on the bottom of each raceway and a distribution area with cover plate supports standard electrical mounting hardware. Note: All electrical wiring should be done by a certified electrician.

ECM-3BP Module Cover Plate

The ECM-RACEWY3 can hold up to three ETA-ECM20/30 Modules and the ECM-RACEWY6 can hold up to six ETA-ECM20/30 Modules. If using fewer modules than the housing will hold, the open slots can be covered using an ECM Module Blank Plate. Two of these are included with the ECM-RACEWY6. If additional Blank Plates are required, they can be purchased in packages of three.

All cover plates must be secured tightly. For safety, there should be no open slots when the raceway is in use. Top and bottom mounting tabs are incorporated to mount inside an Atlas Rack. All rack mount rails are designed to be removed if they are not needed; simply bend the tab back and forth until the tab breaks. Be careful of sharp edges.

ECM Data Wire and Distance

There are six ECM control ports on the ETA-ECS6RM and up to six ECM Modules can be connected to it. There are many types of ECM Modules that require the same interface connectivity to the ETA-ECS6RM. All ECM Modules can be interfaced with the ETA-ECS6RM. For connection between the ETA-ECS6RM and an ECM module, use a 5 conductor cable that is a minimum of 22 gauge wire. It is recommended to use CAT5 cable due to the common availability and low cost. Pay special attention to the port connections and DO NOT MISS WIRE or damage may occur. The distance between the ETA-ECS6RM and the ECM Module can be up to 1000ft.

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800-321-6699 • Fax: 800-996-3821

– 7 –

ETAsys.com

Specifications are subject to change without notice.

Image 7
Contents ETA-ECM30 Table of Contents Important Safety Instructions ETA-ECM30 Introduction KEY FeaturesApplications Trigger/Status Port Pin Identification Front Panel FeaturesECM-RACEWY1 ECM-RACEWY3 ECM-RACEWY6 ECM Housing TypesECM Module Activation Without Using AN ETA-ECS6RM Controller Wiring the ETA-ECM30 Control Module Front Panel ETA-ECM30 SpecificationsETA-ECM30 Service Limited Warranty
Related manuals
Manual 1 pages 27.53 Kb

ETA-ECM30 specifications

The ETA Systems ETA-ECM30 is a cutting-edge energy management and monitoring solution designed for efficient power distribution and optimization across various applications. This advanced system is built to cater to the needs of both commercial and industrial settings, providing robust functionalities that ensure optimal energy utilization.

One of the standout features of the ETA-ECM30 is its real-time monitoring capability. The device continuously tracks energy consumption patterns, allowing users to make informed decisions to enhance efficiency and lower operational costs. The high-resolution display provides clear visual data, highlighting key metrics such as voltage, current, power factor, and total energy consumption. These metrics are crucial for identifying areas that require improvement.

Incorporating advanced communication technologies, the ETA-ECM30 supports various protocols including Modbus, Ethernet, and RS-485. This ensures seamless integration with existing infrastructure, facilitating remote monitoring and control. The ability to interact with other intelligent devices within an energy management system creates a cohesive network, enabling sophisticated automation and optimization strategies.

The ETA-ECM30 also boasts extensive data logging capabilities, archiving historical data that can be analyzed to identify trends over time. This functionality is essential for predictive maintenance and long-term planning, providing users with insights that can lead to significant operational improvements.

Safety and compliance are paramount in energy systems, and the ETA-ECM30 meets high standards in both areas. It features overload protection, surge suppression, and fault detection, ensuring the safety of both the equipment and users. Furthermore, it complies with industry regulations and standards, making it a reliable choice for discerning businesses.

User-friendliness is another essential aspect of the ETA-ECM30. The device is designed with an intuitive interface, making it accessible for users with varying levels of technical expertise. Easy navigation allows for quick setup and configuration, reducing the time and effort needed to get the system operational.

In summary, the ETA Systems ETA-ECM30 is an innovative energy management solution that combines real-time monitoring, advanced communication technologies, comprehensive data logging, and robust safety features. Its user-friendly design and high compatibility make it an ideal choice for businesses aiming to enhance their energy efficiency and reduce costs while complying with safety standards. Whether in a commercial or industrial environment, this system is equipped to deliver superior performance and reliability.