APC AP9617 manual Event Recipients, Trap Receiver settings, Email options

Page 77

USER’S GUIDE network management card

®

Event Recipients

Overview

The Web interface and control console both have options that allow you to define up to four trap receivers and up to four e-mail addresses to be used when an event occurs that has the SNMP traps or e-mail enabled. See Event Actions (Web Interface only).

Trap Receiver settings

To access the Trap Receiver settings that allow you to define which NMSs will receive traps:

In the Web interface, use the Recipients option in the Events menu.

In the control console, use the SNMP option in the Network menu.

Item

Definition

 

 

Community Name

This setting defines the password (maximum of 15

 

characters) used when traps are sent to the NMS

 

identified by the Receiver NMS IP setting.

 

 

Receiver NMS IP

Identifies by IP address the NMS that will receive traps.

 

If this setting is 0.0.0.0 (the default value), traps will not

 

be sent to any NMS.

 

 

Generation (Web interface)

Enables (by default) or disables the sending of any traps

Trap Generation (control

to the NMS identified by the Receiver NMS IP setting.

 

console)

 

 

 

Authentication Traps

Enables or disables the sending of authentication traps

 

to the NMS identified by the Receiver NMS IP setting.

 

 

Email options

See E-mail Feature.

75

Image 77
Contents USER’S Guide network management card ContentsSecurity Introduction FeaturesProduct Description Initial set-upPlant Network management featuresOverview Internal Management FeaturesAccess priority for logging on Types of user accounts Introduction Feature DescriptionFront Panel Condition Description Link-RX/TX 10/100 LEDStatus LEDs Network interface watchdog mechanism Watchdog FeaturesResetting the network timer Control Console How To Log OnRemote access to the control console To connect Type 1 equipment Local access to the control consoleTo connect Type 2 equipment How to Recover from a Lost Password Example main screen Main ScreenMain screen information fields Information and status fieldsMain screen status fields Main menu Control Console MenusDevice Manager option Menu structureSystem option Network optionWeb menu options Web InterfaceIntroduction Supported Web browsers How to Log On URL address formats Example Web SummaryHelp icon on quick status tab Summary page fieldsEvents menu Data menu Network menu System menu Navigation MenuTo do the following, see Data Menu Web Interface Only Selecting a menu to perform a taskHelp menu Links menu Menu options Network MenuTCP/IP Option SettingsDNS Ping utility control console FTP Server, and Telnet & Web options Snmp Setting DefinitionUSER’S Guide network management card System Menu Menu options Identification Administrator and Device Manager UserUser Manager Date & Time Weeks maximum. Use Update Using NTP Now toAction Definition ToolsPreferences Web interface APC’s Web Site , Testdrive Demo , and Remote Monitoring Links Web interfaceAbout System Status Options System and battery statusWeb interface. The Web interface displays the DC Power Plant USER’S Guide network management card Management Options DC Power Plant optionsDC System DC System Parameters & OEM Parameters Menu Item Description Enabled. See Battery Thresholds Rectifier Parameters Description Power Modules Rectifiers and ConvertersViolated. See Rectifier Parameters Rectifier Alarms DescriptionUSER’S Guide network management card Status Field Description Converter Parameters Description Converter Alarms Description USER’S Guide network management card Status Field Description Distribution Breakers and Fuses Thresholds Batteries Status, Thresholds and AlarmsUSER’S Guide network management card USER’S Guide network management card USER’S Guide network management card USER’S Guide network management card Relays Output Relays and Input Relays Menu Item for LVD Description LVD Low Voltage DisconnectPower Plant Alarms/Internal Log About DC Power Plant System Event-Related Menus Menu options Logged events Event LogControl console Web interfaceHow to use FTP to retrieve log files Ftpget event.txt or Ftpget data.txt Event Actions Web Interface only Snmp traps action Severity levelsEvent log action Email action Email options Trap Receiver settingsEvent Recipients DNS servers Mail FeatureEmail Recipients Smtp settingsSetting Description USER’S Guide network management card USER’S Guide network management card Detailed Event Action Configuration How to Configure Individual EventsEvent List Code Description SeverityLog Option Data Menu Web Interface OnlyConfiguration Option Planning and implementing security features Security FeaturesUser names, passwords, community names SecurityInterface Security Access Summary of access methodsFirewalls AuthenticationAuthentication versus encryption Management Card access problems TroubleshootingProblem Solution Management CardSETs to the mconfigTrapReceiverTable OIDs, or use Snmp issuesQuery the mconfigTrapReceiverTable PowerNet MIB Limited warranty Warranty and ServiceWarranty limitations Product InformationObtaining Service Examples of life-support devices Life-Support PolicyGeneral policy USER’S Guide network management card Specification SpecificationsElectrical PhysicalNumerics IndexCompensation Method Email action, configuring for events Email Recipients Hardware Voltage Alarm NMS Guide management card TCP/IP Xmodem USA APC Worldwide Customer SupportCopyright
Related manuals
Manual 19 pages 40.93 Kb

AP9617 specifications

The APC AP9617 is a vital component for data center management and power management solutions, designed by APC by Schneider Electric. This intelligent network management card is engineered to provide enhanced monitoring and control of uninterruptible power supplies (UPS), ensuring consistent power availability and optimal performance in a variety of environments.

One of the main features of the AP9617 is its ability to connect via Ethernet, enabling remote monitoring and management of the UPS status through a web interface. This functionality allows users to access real-time data on power consumption, voltage levels, and overall system health from anywhere with internet connectivity. The card supports both SNMP (Simple Network Management Protocol) and web protocols, making it compatible with various network environments.

The AP9617 also comes equipped with advanced alerting capabilities. Users can configure email and SNMP traps to receive notifications about critical events, such as power outages, battery failures, or temperature fluctuations. This proactive alert system ensures that administrators can respond quickly to potential issues, minimizing downtime and protecting valuable equipment.

In terms of security, the AP9617 incorporates robust measures, including Secure Sockets Layer (SSL) for encrypted communications, ensuring that data transmitted over the network is protected from unauthorized access. Additionally, it supports user authentication and configurable access rights, allowing system administrators to maintain strict control over who can view or modify the UPS settings.

Physical characteristics of the APC AP9617 include a compact form factor that allows it to be easily integrated into existing UPS units without taking up excessive space. The installation process is straightforward, enabling users to deploy the device quickly and efficiently.

With its emphasis on reliability and performance, the AP9617 plays a critical role in power management strategies. By providing detailed analytics and reporting tools, it helps organizations analyze power usage trends, identify inefficiencies, and plan for future energy needs.

In summary, the APC AP9617 is more than just a network management card; it is an essential tool for ensuring the resilience and efficiency of power systems in data centers and other critical applications. Through its innovative features, technologies, and strong security protocols, it enables organizations to maintain power continuity while optimizing energy management practices.