SWITCHES 127
OP and LN Series Enclosed Basic Switches
| LN switches can withstand rapid | |
| actuating plunger cannot reach the precision switch unit inside. Individual seals | |
| around each leadwire and cover plate protect the switch cavity from condensation, | |
| oil, and dust. OP enclosed switches are precision | |
| rugged | |
OP and LN enclosed basic switches | contaminants on |
|
Features u | Benefits u | Applications u |
• LN: | • #14 HWM wire leads (LN Series) | • Machine tools |
• LN: Positioning dowel holes | • | • Stamping machines |
• OP: Cover seal and captive cover screws | • | • Applications where shock and |
• OP: Mounts from four sides | • Sealing: NEMA 1, 3, 4, and 13 | vibration are present |
• OP: Roller arm adjustable through 360º | • Operating temperature: |
|
|
|
Product Specifications u
|
|
| Voltage Rating |
| Current Rating | Operating | Pretravel | Differential |
| ||
Part Number | Description | Mounting |
|
|
|
|
| Force | Travel | Overtravel | |
VAC | VDC | AC |
| DC | (inches) | ||||||
|
|
|
| (lb.) | (inches) |
| |||||
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
SPDT, straight plunger, | 480 | 250 | 15 |
| 0.25 | 5 | 0.004 | 0.203 inch | |||
1 ft. wire leads |
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
15A, SPDT, adjustable roller | NA | NA | NA | NA |
| NA | 0.219 | 0.007 | 90º | ||
lever, clockwise actuation |
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
Same as | NA | NA | NA | NA |
| NA | 0.219 | 0.007 | 90º | ||
mounting bracket |
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
10A, DPDT, adjustable roller | NA | NA | NA | NA |
| NA | 0.250 | 0.109 | 25º | ||
lever, clockwise actuation |
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
Arrow Industrial Selector Guide
www.arrownac.com/industrial